Search Photometer PrimeLab 2.0 SOLO Water-i.d. GmbH (460491)

Water-i.d. GmbH (460491)

Photometer PrimeLab 2.0 SOLO
The photometer with 18 different wavelengths (3 sensors with 6 wavelengths) covers the full VIS-spectrum as well as key parts of UV and IR spectrum. LEDs are set up at 180° as well as at 90° to enable NTU-Turbidity, PTSA and Fluorescein measurements as well.<...
Photometer PrimeLab 2.0 SOLO
The photometer with 18 different wavelengths (3 sensors with 6 wavelengths) covers the full VIS-spectrum as well as key parts of UV and IR spectrum. LEDs are set up at 180° as well as at 90° to enable NTU-Turbidity, PTSA and Fluorescein measurements as well.


-5.5" colour HD touch-display
-More than 140 different parameter methods (paid activation required)
-Please order reagents separately
-Auto-calibration function
-Intelligent OTZ (One-Time-Zero) function
-Can be used with 1 ml, 16 mm and 24 mm cuvettes
-Data management with free software (LabCOM) / app in free cloud including individual accounts and reporting system


Scope of supply:
Multitest Photometer PrimeLab 2.0, 1 x 24 mm cuvette adapter
Spectral range: 390 ... 950 nm, 18 wavelengths
Ambient temperature: 5 ... 45 °C
Rel. humidity: 30 ... 90 %
Internal memory: 150000 measurements
Datatransfer: WiFi, GSM
Software: LabCOM software, LabCOM App, LabCOM Cloud
Power supply: 8500 mA Li-Io battery, 5 V power supply with adapters
Warranty: 2 years
PN Manuf. PN Supplier Description Dimensions (W x D x H)~mm PK Weight~g Protection class General Price Quantity Status Add
4683786 PL02B-SOLO WATER-i.d. GmbH PrimeLab 2.0 SOLO 100 x 255 x 59 1 715 IP 54 1095.29 EU Search Please contact us
Search Photometer PrimeLab 2.0 starter-kit Water-i.d. GmbH (460502)

Water-i.d. GmbH (460502)

Photometer PrimeLab 2.0 starter-kit
The photometer with 18 different wavelengths (3 sensors with 6 wavelengths) covers the full VIS-spectrum as well as key parts of UV and IR spectrum. LEDs are set up at 180° as well as at 90° to enable NTU-Turbidity, PTSA and Fluorescein measurements as...
Photometer PrimeLab 2.0 starter-kit
The photometer with 18 different wavelengths (3 sensors with 6 wavelengths) covers the full VIS-spectrum as well as key parts of UV and IR spectrum. LEDs are set up at 180° as well as at 90° to enable NTU-Turbidity, PTSA and Fluorescein measurements as well.


-5.5" colour HD touch-display
-More than 140 different parameter methods (paid activation required)
-Please order reagents separately
-Auto-calibration function
-Intelligent OTZ (One-Time-Zero) function
-Can be used with 1 ml, 16 mm and 24 mm cuvettes
-Data management with free software (LabCOM) / app in free cloud including individual accounts and reporting system


Scope of supply:
Multitest Photometer PrimeLab 2.0, carrying case, 4 x 24 mm/10 ml glass cuvettes with lid, light-shield, 24 mm cuvette adapter, stirring rod, 10 ml plastic syringe, cleaning brush, battery-charger with USB-cable (type C)
Spectral range: 390 ... 950 nm, 18 wavelengths
Ambient temperature: 5 ... 45 °C
Rel. humidity: 30 ... 90 %
Internal memory: 150000 measurements
Datatransfer: WiFi, GSM
Software: LabCOM software, LabCOM App, LabCOM Cloud
Power supply: 8500 mA Li-Io battery, 5 V power supply with adapters
Warranty: 2 years
PN Manuf. PN Supplier Description Dimensions (W x D x H)~mm PK Weight~g Protection class General Price Quantity Status Add
4683785 PL02B WATER-i.d. GmbH PrimeLab 2.0 starter-kit 100 x 255 x 59 1 715 IP 54 1490.15 EU Search Please contact us
Search Photometer PrimeLab 2.0 starter-kit, all parameters activated, except turbidity (NTU)/PTSA/fluores Water-i.d. GmbH (462605)

Water-i.d. GmbH (462605)

Photometer PrimeLab 2.0 starter-kit, all parameters activated, except turbidity (NTU)/PTSA/fluorescein
The photometer with 18 different wavelengths (3 sensors with 6 wavelengths) covers the full VIS-spectrum as well as key parts of UV and IR spectrum. LEDs are set up at 180° as well as a...
Photometer PrimeLab 2.0 starter-kit, all parameters activated, except turbidity (NTU)/PTSA/fluorescein
The photometer with 18 different wavelengths (3 sensors with 6 wavelengths) covers the full VIS-spectrum as well as key parts of UV and IR spectrum. LEDs are set up at 180° as well as at 90° to enable NTU-Turbidity, PTSA and Fluorescein measurements as well.


-5.5" colour HD touch-display
-More than 140 different parameter methods
-Turbidity (NTU)/PTSA/fluorescein is not activated
-Please order reagents separately
-Auto-calibration function
-Intelligent OTZ (One-Time-Zero) function
-Can be used with 1 ml, 16 mm and 24 mm cuvettes
-Data management with free software (LabCOM) / app in free cloud including individual accounts and reporting system


Scope of supply:
Multitest Photometer PrimeLab 2.0, carrying case, 10 x 24 mm/10 ml glass cuvettes with lid, light-shield, 16 and 24 mm cuvette adapters, stirring rod, 10 ml plastic syringe, cleaning brush, battery-charger with USB-cable (type C), 20 ml luer lock syringe, filter adapter, 2 cans with 50 filter papers, 100 ml can with lid
Spectral range: 390 ... 950 nm, 18 wavelengths
Ambient temperature: 5 ... 45 °C
Rel. humidity: 30 ... 90 %
Internal memory: 150000 measurements
Datatransfer: WiFi, GSM
Software: LabCOM software, LabCOM App, LabCOM Cloud
Power supply: 8500 mA Li-Io battery, 5 V power supply with adapters
Warranty: 2 years
PN Manuf. PN Supplier Description Dimensions (W x D x H)~mm PK Weight~g Protection class General Price Quantity Status Add
6322094 PL02BALL-WO90 WATER-i.d. GmbH PrimeLab 2.0 starter-kit, all parameters activated, except turbidity (NTU)/PTSA/fluorescein 100 x 255 x 59 1 715 IP 54 1888.71 EU Search Please contact us
Search Photometer PrimeLab 2.0 starter-kit, with turbidity (NTU) Water-i.d. GmbH (460507)

Water-i.d. GmbH (460507)

Photometer PrimeLab 2.0 starter-kit, with turbidity (NTU)
The photometer with 18 different wavelengths (3 sensors with 6 wavelengths) covers the full VIS-spectrum as well as key parts of UV and IR spectrum. LEDs are set up at 180° as well as at 90° to enable NTU-Turbidity, PTSA and Fluor...
Photometer PrimeLab 2.0 starter-kit, with turbidity (NTU)
The photometer with 18 different wavelengths (3 sensors with 6 wavelengths) covers the full VIS-spectrum as well as key parts of UV and IR spectrum. LEDs are set up at 180° as well as at 90° to enable NTU-Turbidity, PTSA and Fluorescein measurements as well.


-5.5" colour HD touch-display
-More than 140 different parameter methods (paid activation required)
-Please order reagents separately
-Preactivated parameters: turbidity (NTU)
-Auto-calibration function
-Intelligent OTZ (One-Time-Zero) function
-Can be used with 1 ml, 16 mm and 24 mm cuvettes
-Data management with free software (LabCOM) / app in free cloud including individual accounts and reporting system


Scope of supply:
Multitest Photometer PrimeLab 2.0, carrying case, 4 x 24 mm/10 ml glass cuvettes with lid, light-shield, 24 mm cuvette adapter, stirring rod, 10 ml plastic syringe, 1 x 1 - 10 ml lab pipette with 2 tips, 1 x NTU-Turbidity calibration kit, cleaning brush, battery-charger with USB-cable (type C), printed user manual
Spectral range: 390 ... 950 nm, 18 wavelengths
Ambient temperature: 5 ... 45 °C
Rel. humidity: 30 ... 90 %
Internal memory: 150000 measurements
Datatransfer: WiFi, GSM
Software: LabCOM software, LabCOM App, LabCOM Cloud
Power supply: 8500 mA Li-Io battery, 5 V power supply with adapters
Warranty: 2 years
PN Manuf. PN Supplier Description Dimensions (W x D x H)~mm PK Weight~g Protection class General Price Quantity Status Add
6318781 PL02B-TRB WATER-i.d. GmbH PrimeLab 2.0 starter-kit, with turbidity (NTU) 100 x 255 x 59 1 715 IP 54 1215.53 EU Search Please contact us
Search Reference standards for Photometer PrimeLab 2.0 Water-i.d. GmbH (460354)

Water-i.d. GmbH (460354)

Reference standards for Photometer PrimeLab 2.0
Reference standards for Photometer PrimeLab 2.0
PN Manuf. PN Supplier Description PK Volume~ml General Price Quantity Status Add
4683835 PL2SP-REFTRB WATER-i.d. GmbH Reference standard 0.5 / 10 / 1000 NTU 3 10 112.94 EU Search Please contact us
4683836 PL2SP-REFPTSA WATER-i.d. GmbH Reference standard 500 μg/l PTSA, deionised water 2 100 83.09 EU Search Please contact us
5 items found Page 1 of 1
BDL to-top