Loading...
You Searched For:

Your filters:
Search Falling Ball Viscometer HAAKE™ Type C Thermo Electron GmbH (Haake) (5558)

Thermo Electron GmbH (Haake) (5558)

Falling Ball Viscometer HAAKE™ Type C
To precisely measure the viscosity of low-viscosity, transparent Newtonic liquids and gasses per DIN 53015/ISO 12058 specifications.

Supplied with: HAAKE falling ball viscometer, type C with 6 balls, thermometer -1 to 26 °C in 0.1...
Falling Ball Viscometer HAAKE™ Type C
To precisely measure the viscosity of low-viscosity, transparent Newtonic liquids and gasses per DIN 53015/ISO 12058 specifications.

Supplied with: HAAKE falling ball viscometer, type C with 6 balls, thermometer -1 to 26 °C in 0.1 °C increments, cleaning unit, test certificate and operating instructions
PN Manuf. PN Supplier PK Type Viscosity Standard Max. Viscosity~mPa·s Reproducibility~% Min. viscosity~mPa·s General Price Quantity Status Add
9885021 356-0001 Thermo Electron GmbH (Haake) 1 C 0.5 ... 100,000 mPa·s DIN 53015, ISO 12058 100000 <0,5 0.5 4640.21 EU Search Please contact us
Search Viscometer SV-10 / SV-100 A&D Instruments Limited (7460)

A&D Instruments Limited (7460)

Viscometer SV-10 / SV-100
Sine-wave Vibro Viscometer SV-10/SV-100 measures viscosity by detecting the driving electric current necessary to resonate the two sensor plates at constant frequency of 30 Hz and amplitude of less than 1 mm.

-Wide range of measurements
-Temperature me...
Viscometer SV-10 / SV-100
Sine-wave Vibro Viscometer SV-10/SV-100 measures viscosity by detecting the driving electric current necessary to resonate the two sensor plates at constant frequency of 30 Hz and amplitude of less than 1 mm.

-Wide range of measurements
-Temperature measurements: 0 to 160 °C
-High accuracy: ±1% of measured value
-Small sample size of 35 ml and optional 10 ml sample vial or 13 ml quartz glass vial
-Easy cleaning of stainless steel sensor plates and temperature sensor (all gold plated)
-WinCT-Viscosity is software to import the measured data of viscosity and temperature to a PC and graphically display the changes in real-time for your analysis
-Easy calibration with distilled water (SV-10)
-Sample heating or cooling with "Water Jacket"
-Approved measuring method acc. to JCSS (Japan Calibration Service Systems)
PN Manuf. PN Supplier Measuring range PK Type Unit General Price Quantity Status Add
9901560 SV-10 A&D Instruments Limited 0.3 ... 10000 mPas 1 SV-10 mPAs, Pas, cP, P 9162.02 EU Search Please contact us
9901561 SV-100 A&D Instruments Limited 1 ... 100 Pas 1 SV-100 Pas, P 9162.02 EU Search Please contact us
2 items found Page 1 of 1
BDL to-top