Home
Newsletters
Portfolio
Company
Download
Service
Contact
Log In
Register
My cart
-1
My Quotes
Webshop
A-B Search
Webshop
A-B Search
Log In
Register
My cart
-1
My Quotes
Home
Newsletters
Portfolio
Company
Download
Service
Contact
×
Loading...
Home
AB Search
HOME
AB Search
You Searched For:
Your filters:
×
controllers
Biological Indicators Attest for Control of Steam Autoclaves
3M Deutschland GmbH (637)
Biological Indicators Attest™ for Control of Steam Autoclaves
Biological control involves the use of indicators, which check whether all microorganisms were killed during the sterilisation process. The bio-indicators are unique, as they directly indicate how many microbial spores h...
Biological Indicators Attest™ for Control of Steam Autoclaves
Biological control involves the use of indicators, which check whether all microorganisms were killed during the sterilisation process. The bio-indicators are unique, as they directly indicate how many microbial spores have actually been killed. Thanks to the reliability and quality of the information, the regular use of a bio-indicator can lead to an improvement in the performance of the sterilisation process and thus to better results.
Features:
-No external laboratory is required for performance evaluation
-Easy handling
-Reasonable to use after repairs or maintenance of autoclaves
Application:
-Program 3.5 minutes, holding time at 121 °C or 134 °C
-After sterilisation, break the vial in order to bring the nutrient solution into contact with the spore strip
-Results in 48 hours
-Meets EN ISO 11138 standard
More Info
PN
Manuf. PN
Supplier
PK
Type
General
Price
Quantity
Status
Add
6089578
7000002535
3M Deutschland GmbH
100
Biological Indicators Attest™ for steam autoclaves, brown cap
578.53 EU
6280367
7000053442
3M Deutschland GmbH
100
Biological Indicators Attest™ for steam autoclaves, blue cap
656.47 EU
Autoclave thermometer
Bel-Art Products (3419)
Autoclave thermometer
Durable bi-metal thermometer with a maximum registering pointer (red), moved up by the temperature measuring pointer, (black), to indicate the highest temperature achieved, and remains there until it is manually reset.
-Traceable to NIST Standard
-Threaded con...
Autoclave thermometer
Durable bi-metal thermometer with a maximum registering pointer (red), moved up by the temperature measuring pointer, (black), to indicate the highest temperature achieved, and remains there until it is manually reset.
-Traceable to NIST Standard
-Threaded connection (1/4" NPT), screws directly into in-line processes, can be used to mount thermometer on included stand
-Waterproof and pressurised, withstands autoclave cycles and has a removable protective silicone sleeve to prevent moisture from making contact with the dial
-Constructed from 304 stainless steel with a glass lens; withstands pressure, high temperatures and rust
-Tested and inspected in the USA
-Includes a multi-language (English, French, German, Italian, Portuguese, and Spanish) Statement of Accuracy and instructions
-Available as an option with an individual Thermometer Calibration Report
Specifications
Measuring range: -20 to +150 °C
Probe length: 50 mm
More Info
PN
Manuf. PN
Supplier
Description
PK
General
Price
Quantity
Status
Add
6287577
B61315-0000
Bel-Art Products
Autoclave thermometer
1
146.76 EU
Screw Cap GL 45 thermocouple holder, DURAN
DWK Life Sciences GmbH (Duran) (2792)
Screw Cap GL 45 thermocouple holder, DURAN®
The DURAN® Screw Cap GL 45 thermocouple holder consists of a holder fitted into a blue DURAN® polypropylene GL 45 cap that accepts up to three separate thermocouple wires used in autoclaves or sterilizers.
Applications...
Screw Cap GL 45 thermocouple holder, DURAN®
The DURAN® Screw Cap GL 45 thermocouple holder consists of a holder fitted into a blue DURAN® polypropylene GL 45 cap that accepts up to three separate thermocouple wires used in autoclaves or sterilizers.
Applications
-"Loaded Chamber heat penetration" tests during Performance Qualification (PQ)
-Routine sterilization /autoclave cycles
-Performance tests after autoclave maintenance or repair
Features
-Usable with DURAN® original GL 45 laboratory bottles (1000 ml or less).
-The 240 mm PTFE tube may be cut to length
-Suitable for holding up to three separate thermocouple wires (Conductor sizes 1/0.3 mm, 1/0.5 mm or 7/0.2 mm)
-Retrace code for product traceability and downloadable certificate
More Info
PN
Manuf. PN
Supplier
Colour
Material
PK
Thread
Cap size
autoclavable
Thread Ø
General
Price
Quantity
Status
Add
9072179
299922802
DWK Life Sciences GmbH (Duran)
PP
1
GL45
237.79 EU
Screw Cap GL 45 with temperature probe holder, DURAN
DWK Life Sciences GmbH (Duran) (2791)
Screw Cap GL 45 with temperature probe holder, DURAN®
The DURAN® temperature probe holder GL 45 consists of a stainless steel holder that is permanently fitted into a blue DURAN® polypropylene GL 45 cap. The holder will accept the 6.0 mm metal temperature measuring probes tha...
Screw Cap GL 45 with temperature probe holder, DURAN®
The DURAN® temperature probe holder GL 45 consists of a stainless steel holder that is permanently fitted into a blue DURAN® polypropylene GL 45 cap. The holder will accept the 6.0 mm metal temperature measuring probes that are commonly used in laboratory autoclaves and sterilizers.
Applications
-Routine sterilization /autoclave cycles
-"Loaded Chamber heat penetration" tests during Performance Qualification (PQ)
-Performance tests after autoclave maintenance or repair
Features
-Usable with DURAN® original GL 45 laboratory bottles (1000 ml or less).
-The depth of the probe can be adjusted to suit the bottle size
-Adjustable ferrule suitable for 6.0 mm diameter probes
-Retrace code for product traceability and downloadable certificate
-Easy positioning of the sensor in the middle of the bottle
More Info
PN
Manuf. PN
Supplier
Colour
Material
PK
Thread
Cap size
autoclavable
Thread Ø
General
Price
Quantity
Status
Add
9072178
299912801
DWK Life Sciences GmbH (Duran)
PP
1
GL45
183.82 EU
×
20
50
100
4 items found
Page 1 of 1
Login Modal
×