Search Accessories for Gas Warining Device X-am 7000 Dräger Safety AG & Co. KGaA (4991)

Dräger Safety AG & Co. KGaA (4991)

Accessories for Gas Warining Device X-am® 7000
This device is the innovative solution for the simultaneous and continuous detection of up to five gases. A combination of more than 25 sensors allows flexible solutions to individual monitoring tasks. The device can be equipped with thr...
Accessories for Gas Warining Device X-am® 7000
This device is the innovative solution for the simultaneous and continuous detection of up to five gases. A combination of more than 25 sensors allows flexible solutions to individual monitoring tasks. The device can be equipped with three electrochemical, and two catalytic bead, infrared or photoionisation sensors. It is the ideal companion in a great number of applications where reliable monitoring of oxygen, toxic and combustible gases and vapors in ambient air is necessary.

Basic unit with rubber-boot, carrying strap, calibration adapter, water and dust filter. In order to get a fully operational unit, a power pack and up to 5 sensors have to be ordered. And, optionally, a built-in pump or a datalogger can be ordered.
Specifications
Temperature:
Pressure:
Humidity: -20 ... +55 °C, short-term -40 ... +60 °C
700 ... 1300 hPa
10 ... 95 % r.F.
Alarms (visual/audible): 360° flashing LEDs / >100 dB(A) at 30 cm
Charging time: 3.5 to 7 hours, depending on battery type
Pump mode: maximum hose length of 45 m
Dimensions (W x H x D): 150 x 140 x 75 mm
Weight (basic unit/battery): 600 g / 490 g (3,0 Ah), 730 g (6,0 Ah)
Ingress protection: IP 67
Approvals: ATEX, MED, CSA, IECEx
PN Manuf. PN Supplier PK Type General Price Quantity Status Add
6227132 8316487 Dräger Safety AG & Co. KGaA 1 Charging module 292.65 EU Search Please contact us
6267866 8316994 Dräger Safety AG & Co. KGaA 1 Power supply (worldwide) for 2 charging modules 188.24 EU Search Please contact us
7619120 8317805 Dräger Safety AG & Co. KGaA 5 Set sensor membrane 80.88 EU Search Please contact us
7619121 8318607 Dräger Safety AG & Co. KGaA 1 Set pump membrane 140.45 EU Search Please contact us
7656801 8318169 Dräger Safety AG & Co. KGaA 1 Car mounting kit 140.45 EU Search Please contact us
7657622 8317836 Dräger Safety AG & Co. KGaA 1 Sealing plate complete 351.47 EU Search Please contact us
Search Carbon Dioxide Safety Monitor AX60 Analox Ltd. (617)

Analox Ltd. (617)

Carbon Dioxide Safety Monitor AX60
Gas warning device for precise measurement of the amount of CO2 in the air. 3 alarm settings factory set: Time-weighted average (TWA) alarm (5000 ppm; 0.5% CO2), Low alarm (15,000 ppm; 1.5% CO2) and High alarm (30,000 ppm; 3% CO2)
-No calibration req...
Carbon Dioxide Safety Monitor AX60
Gas warning device for precise measurement of the amount of CO2 in the air. 3 alarm settings factory set: Time-weighted average (TWA) alarm (5000 ppm; 0.5% CO2), Low alarm (15,000 ppm; 1.5% CO2) and High alarm (30,000 ppm; 3% CO2)
-No calibration required (unless local regulations state otherwise)
-Very long life sensor can last up to 15 years
-Up to 4 x CO2sensors and 8 x CO2 alarms can be used per Central Display Unit
-Supplied with a relay on each alarm which can be used to trigger ventilation, extraction or a building management system
-Easy installation and maintenance can be conducted by the user
-Additional (quick connect) CO2 sensors and alarms available if more than one entrance to the laboratory or more than one risk area
-Assists in compliance with Exposure Limit regulations such as EH40

Scope of delivery: wall-mounted central display unit, CO2 sensor and CO2 alarm which can provide an early warning of a CO2 leak.
Specifications:
Range :
Accuracy : 0.1 to 5 % CO2
+/- 5 % of alarm setpoint
Alarm intensity : 88 dbA
Monitor Display : 16 digit 2 line LCD in ppm
TWA Alarm : 5,000 ppm (0.5 %) over 8 hours
CO2 Alarms : 15,000 ppm (1.5 %) and 30,000 ppm (3 %)
Operating Temperature : -5 to 50 °C
Central Unit Dimensions : 175 x 110 x 75 mm
Sensor & Alarm Dimensions : 72 x 170 x 45 mm
IP Rating : IP55 (IP54 Central Display Unit)
Warranty : 5 years for electronics and sensor
PN Manuf. PN Supplier Description PK General Price Quantity Status Add
6284262 AP1 Analox Ltd. Ax60 CO2 Safety Monitor 1 931.80 EU Search Please contact us
6284263 AX60SAQYA Analox Ltd. Additional CO2 Sensor (Max 4 per Central Display Unit) 1 423.24 EU Search Please contact us
6284264 AX60RQYBA Analox Ltd. Additional CO2 Alarm (Max 8 per Central Display Unit) 1 168.68 EU Search Please contact us
6284265 P0159-4305K Analox Ltd. Optional Sensor Protector Kit: Protector bar, splashguard and fixing kit 1 71.91 EU Search Please contact us
Search Gas analyzers MAT1100/MAT1200 A. Krüss Optronic GmbH (2794)

A. Krüss Optronic GmbH (2794)

Gas analyzers MAT1100/MAT1200
Gas analyzers MAT1000 series are used for measuring oxygen concentrations (O2) or optional carbon dioxide concentrations (CO2).
Applies to all models of MAT1000 series:
-Easy and intuitive operation via touchscreen, even by untrained personnel
-Crea...
Gas analyzers MAT1100/MAT1200
Gas analyzers MAT1000 series are used for measuring oxygen concentrations (O2) or optional carbon dioxide concentrations (CO2).
Applies to all models of MAT1000 series:
-Easy and intuitive operation via touchscreen, even by untrained personnel
-Create your own method
-Available method parameters: scales, measurement procedures, limit values, comment and much more
-Selectable measurement methods: single or continuous
-Several single measurement procedures: manual, automatic, min/max detection
-Shortcut keys for most important functions
-Short measurement period, high accuracy even with small sample volume
-Validation possible
-Compliance with global standards such as GMP/GLP and 21 CFR Part 11
-Documentation of all measured values of the last 999 measurements
-Integrated interfaces, flexible data export (USB, Ethernet, RS-232)
-Compact design in robust cast aluminum housing
-Built-in air pressure sensor
-Integrated flow rate monitoring
Gas analysers for controlling protective gas packaging. The MAT1100 equipped with an electrochemical oxygen cell measures the oxygen concentration within the range of 0.5 and 35 vol% and with an accuracy of ±0.2 vol%. The MAT1200 additionally features a non-dispersive infrared sensor for measuring carbon dioxide within the range of 0 and 50 vol% and with a high accuracy of ±0.5 vol%. Both devices are suitable for the random sampling as well as the permanent monitoring of the gas mixture used on packaging machines. Their solid metal housing with an interchangeable protective cover offers protection against impact and dirt from the outside.

Measurement of O2 and CO2 e.g. in modified atmosphere packaging, for work with modified atmosphere conditions.
-Sporadic O2 sample checks
-Quick Operation
-Low-drift electrochemical oxygen cell (EC)
-Low-drift carbon non-dispersive infrared sensor (NDIR), model MAT1200
-Combined O2 and CO2 measurement, model MAT1200
-Environmental compensated CO2 measurement, model MAT1200
Specifications
O2 measuring range:
Accuracy:
Resolution: 0.5 to 35 Vol.-%
±0.2 Vol.-%
0.1 Vol.-%
CO2 measuring range (only MAT1200):
Accuracy:
Resolution: 0 to 50 Vol.-%
±0.5 Vol.-%
0.11 Vol.-%
Average measurment period:
Heating time MAT 1100 / MAT1200: 7 to 10 sec
<10 sec / 5 min
Interface: RS-232, USB, Ethernet
Dimensions (W x D x H): 200 x 350 x 150 mm
Weight: 4.6 kg
Power consumption: 60 W
Power supply: 100-250 V, 50/60 Hz
PN Manuf. PN Supplier Description PK Type General Price Quantity Status Add
6269834 MAT1100 A. Krüss Optronic GmbH with oxygen cell 1 MAT1100 7772.06 EU Search Please contact us
6269835 MAT1200 A. Krüss Optronic GmbH with oxygen cell and NDIR carbon dioxide sensor 1 MAT1200 9738.24 EU Search Please contact us