Loading...
You Searched For:

Search Accessories for printer CMB-910 Bellingham + Stanley Ltd. (779572)

Bellingham + Stanley Ltd. (779572)

Accessories for printer CMB-910
Accessories for printer CMB-910
PN Manuf. PN Supplier Description PK General Price Quantity Status Add
4694633 54-02 Bellingham + Stanley Ltd. Printer cable 1 94.12 EU Search Please contact us
4694641 55-85 Bellingham + Stanley Ltd. USB-RS232 converter 1 120.59 EU Search Please contact us
4694643 55-91 Bellingham + Stanley Ltd. Printer paper rolls 1 80.88 EU Search Please contact us
4694644 55-93 Bellingham + Stanley Ltd. Ribbon (black) 1 43.96 EU Search Please contact us
Search Barcode reader Bellingham + Stanley Ltd. (779604)

Bellingham + Stanley Ltd. (779604)

Barcode reader
Barcode reader
PN Manuf. PN Supplier Description PK General Price Quantity Status Add
4694640 55-82 Bellingham + Stanley Ltd. Barcode reader 1 217.65 EU Search Please contact us
Search Digital Refractometer/Polarimeter RePo ATAGO CO.,LTD (3189)

ATAGO CO.,LTD (3189)

Digital Refractometer/Polarimeter RePo
All-in-One refractometer and polarimeter hybrid unit. Only 3 ml sample is needed. With the press of a button, purity, international sugar scale, specific rotation and concentration can be displayed. Users can also set an upper and lower measurement ...
Digital Refractometer/Polarimeter RePo
All-in-One refractometer and polarimeter hybrid unit. Only 3 ml sample is needed. With the press of a button, purity, international sugar scale, specific rotation and concentration can be displayed. Users can also set an upper and lower measurement limit. An indicator light alerts the user if a measurement value is within the limits.

RePo-1: can measure both brix and optical rotation of the sample.
RePo-1 Package includes: Main unit, 100 ml beaker, 50 x Syringe Filters orange 45, 3 x 20 ml Syringes, 100 x Easy filter.

RePo-2: As RePo-1, additionally the RePo-2 also determines and displays the amount of fructose (%) within HFCS. The RePo-2 is ideal for various industries such as food and beverage, or sugar refining.

RePo-3: As RePo-1, additionally the RePo-3 also determines and displays the amount of invert sugar (%) derived from sucrose. The RePo-3 is ideal for various industries such as sugar refining.

RePo-4: As RePo-1, additionally the RePo-4 also determines and displays the amount of fructose (%) and honey moisture (%). The RePo-4 is ideal for total quality control of honey.

RePo-5: As RePo-1, additionally the RePo-5 can also display the refractive index (nD) of a sample. The RePo-5 is ideal for quality control in various industries such as fragrances, cosmetics, or pharmaceutical.
Specifications
Measurement range
Angle of Rotation:
Brix (%):
Temperature:
-5 to +5°
0 to 85 %
15 to 40 °C
Resolution
Angle of Rotation:
Temperature:
Brix (%):
0.01°
0.1 %
0.1 °C
Accuracy
Angle of Rotation:
Brix (%):
Temperature:
±0.1° (at 20 °C)
±0.2 %
±1°C
Working temperature: 5 to 40 °C
Wavelength: 589 nm
Power supply: 4 x Size AAA alkaline battery
Dimensions: 101 x 160 x 38 mm
Weight: 325 g
IP code: IP 67
PN Manuf. PN Supplier For Measuring range PK Type General Price Quantity Status Add
6266905 5010 ATAGO CO.,LTD Sugar -130 - +130°Z 1 RePo-1 2256.02 EU Search Please contact us
6286462 5020 ATAGO CO.,LTD Sugar -130 - +130°Z 1 RePo-1 Package 2225.54 EU Search Please contact us
6286463 5012 ATAGO CO.,LTD Fructose 0.0 - 99.9 % 1 RePo-2 2070.00 EU Search Please contact us
6286464 5013 ATAGO CO.,LTD Inverted sugar 0.0 - 99.9 % 1 RePo-3 2070.00 EU Search Please contact us
6286465 5014 ATAGO CO.,LTD Fructose in Honey /
Honey (moisture)
0.0 - 99.9 % /
13.0 - 30.0 %
1 RePo-4 2070.00 EU Search Please contact us
6286466 5015 ATAGO CO.,LTD Refractive index 1.3306 - 1.5050 nD 1 RePo-5 2256.02 EU Search Please contact us
Search Hand spectroscopes A. Krüss Optronic GmbH (4389)

A. Krüss Optronic GmbH (4389)

Hand spectroscopes
Handy and precise. Angle dispersion C -F: 7°. Linear dispersion: 60 mm (direct vision prism of Amici type)
Ideal for demonstrations in schools and for:
-Viewing / observation of emission and absorption spectra
-Control of the wavelength spectra of gas emission...
Hand spectroscopes
Handy and precise. Angle dispersion C -F: 7°. Linear dispersion: 60 mm (direct vision prism of Amici type)
Ideal for demonstrations in schools and for:
-Viewing / observation of emission and absorption spectra
-Control of the wavelength spectra of gas emission lamps
PN Manuf. PN Supplier PK Type Labeling General Price Quantity Status Add
9841501 HS1501 A. Krüss Optronic GmbH 1 1501 with adjustable split 336.76 EU Search Please contact us
9841504 HS1504 A. Krüss Optronic GmbH 1 1504 with adjustable split and wavelength scale (400 to 750nm) 607.35 EU Search Please contact us
Search Polarimeter ADP430 Bellingham + Stanley Ltd. (779405)

Bellingham + Stanley Ltd. (779405)

Polarimeter ADP430
General purpose single wavelength polarimeter for applications in the sugar, food, chemical, and pharmaceutical industry. Measurements can be performed in angular degrees (°A), sugar (ISS), or user-defined scales. Pre-programmed methods (e.g. PHR-MEAN method, invert su...
Polarimeter ADP430
General purpose single wavelength polarimeter for applications in the sugar, food, chemical, and pharmaceutical industry. Measurements can be performed in angular degrees (°A), sugar (ISS), or user-defined scales. Pre-programmed methods (e.g. PHR-MEAN method, invert sugar, inversion (A-B), and specific rotation) simplify the performance of routine analyses.


-High-resolution 4" HD colour display
-LED light source
-Interference filter with photodiode detector technology
-Continuous measurement and single measurement
-RFID user identification
-Data memory for over 8000 readings
-Measurement up to an optical density of 3.0
-Output as secure PDF possible
-USB (A), USB (B), and Ethernet interface
-Supports FDA Regulation 21 CFR Part 11
-USP/EP/BP compliant
Suitable for applications where internal temperature control is not required, the use of automatic temperature compensation is used, or a water bath is preferred.
PN Manuf. PN Supplier Accuracy Measuring range PK Resolution Type Wavelength~nm Temperature Power supply General Price Quantity Status Add
4694563 37-30 Bellingham + Stanley Ltd. ±0.010 °A
±0.030 °Z
-355 ... 355 °A
-225 ... 225 °Z
1 0.01/0.001 °A
0.01/0.001 °Z
ADP430 589 5 ... 40 °C 100 ... 240 V, 50/60 Hz 15852.65 EU Search Please contact us
Search Polarimeter ADP450 Bellingham + Stanley Ltd. (779409)

Bellingham + Stanley Ltd. (779409)

Polarimeter ADP450
General purpose single wavelength polarimeter for applications in the sugar, food, chemical, and pharmaceutical industry. Measurements can be performed in angular degrees (°A), sugar (ISS), or user-defined scales. Pre-programmed methods (e.g. PHR-MEAN method, invert su...
Polarimeter ADP450
General purpose single wavelength polarimeter for applications in the sugar, food, chemical, and pharmaceutical industry. Measurements can be performed in angular degrees (°A), sugar (ISS), or user-defined scales. Pre-programmed methods (e.g. PHR-MEAN method, invert sugar, inversion (A-B), and specific rotation) simplify the performance of routine analyses.


-High-resolution 4" HD colour display
-LED light source
-Interference filter with photodiode detector technology
-Continuous measurement and single measurement
-RFID user identification
-Data memory for over 8000 readings
-Measurement up to an optical density of 3.0
-Output as secure PDF possible
-USB (A), USB (B), and Ethernet interface
-Supports FDA Regulation 21 CFR Part 11
-USP/EP/BP compliant
-Patented, integrated Peltier temperature control system
-SMART temperature stability
PN Manuf. PN Supplier Accuracy Measuring range PK Resolution Type Wavelength~nm Temperature Power supply General Price Quantity Status Add
4694568 37-50 Bellingham + Stanley Ltd. ±0.010 °A
±0.030 °Z
-355 ... 355 °A
-225 ... 225 °Z
1 0.01/0.001 °A
0.01/0.001 °Z
ADP450 589 15 ... 35 °C 100 ... 240 V, 50/60 Hz 21305.88 EU Search Please contact us
4694569 37-51 Bellingham + Stanley Ltd. ±0.010 °A
±0.030 °Z
-355 ... 355 °A
-225 ... 225 °Z
1 0.01/0.001 °A
0.01/0.001 °Z
ADP450 589 15 ... 35 °C 100 ... 240 V, 50/60 Hz 21305.88 EU Search Please contact us
Search Polarimeter ADP450-HCl Bellingham + Stanley Ltd. (779412)

Bellingham + Stanley Ltd. (779412)

Polarimeter ADP450-HCl
General purpose single wavelength polarimeter for applications in the sugar, food, chemical, and pharmaceutical industry. Measurements can be performed in angular degrees (°A), sugar (ISS), or user-defined scales. Pre-programmed methods (e.g. PHR-MEAN method, inver...
Polarimeter ADP450-HCl
General purpose single wavelength polarimeter for applications in the sugar, food, chemical, and pharmaceutical industry. Measurements can be performed in angular degrees (°A), sugar (ISS), or user-defined scales. Pre-programmed methods (e.g. PHR-MEAN method, invert sugar, inversion (A-B), and specific rotation) simplify the performance of routine analyses.


-High-resolution 4" HD colour display
-LED light source
-Interference filter with photodiode detector technology
-Continuous measurement and single measurement
-RFID user identification
-Data memory for over 8000 readings
-Measurement up to an optical density of 3.0
-Output as secure PDF possible
-USB (A), USB (B), and Ethernet interface
-Supports FDA Regulation 21 CFR Part 11
-USP/EP/BP compliant
-Patented, integrated Peltier temperature control system
-SMART temperature stability
-Glass/PEEK polarimeter tube
-Suitable for tests with hydrochloric acid
PN Manuf. PN Supplier Accuracy Measuring range PK Resolution Type Wavelength~nm Temperature Power supply General Price Quantity Status Add
4694592 37-98 Bellingham + Stanley Ltd. ±0.010 °A
±0.030 °Z
-355 ... 355 °A
-225 ... 225 °Z
1 0.01/0.001 °A
0.01/0.001 °Z
ADP450-HCl 589 15 ... 35 °C 100 ... 240 V, 50/60 Hz 22025.00 EU Search Please contact us
Search Polarimeter ADP600 series Bellingham + Stanley Ltd. (779423)

Bellingham + Stanley Ltd. (779423)

Polarimeter ADP600 series
High-precision polarimeter with Peltier temperature control for applications in pharmacy, chemistry, food industry, and research. Pre-programmed methods (e.g. concentration, invert sugar, inversion (A-B), and specific rotation) simplify the performance of routin...
Polarimeter ADP600 series
High-precision polarimeter with Peltier temperature control for applications in pharmacy, chemistry, food industry, and research. Pre-programmed methods (e.g. concentration, invert sugar, inversion (A-B), and specific rotation) simplify the performance of routine analyses.


-High-resolution 7.4" LCD touchscreen
-Simple menu structure with a method system
-RFID user identification
-UV/VIS lamp with narrow band filter
-Suitable for standard and low volume tubes
-USB (A), USB (B), RS232, and Ethernet interface
-Supports FDA Regulation 21 CFR Part 11
-USP/EP/BP/JP compliant
PN Manuf. PN Supplier Accuracy Measuring range PK Resolution Type Wavelength~nm Temperature Power supply General Price Quantity Status Add
4694578 37-61 Bellingham + Stanley Ltd. ±0.003 °A (589 nm) -355 ... 355 °A 1 0.0001 °A ADP610 589 15 ... 35 °C 100 ... 250 V, 50/60 Hz 31485.29 EU Search Please contact us
4694579 37-62 Bellingham + Stanley Ltd. ±0.003 °A (546/589 nm) -355 ... 355 °A 1 0.0001 °A ADP620 546/589 15 ... 35 °C 100 ... 250 V, 50/60 Hz 32501.47 EU Search Please contact us
4694580 37-63 Bellingham + Stanley Ltd. ±0.003 °A (589 nm)
±0.005 °A (365 nm)
-355 ... 355 °A 1 0.0001 °A ADP622 365/589 15 ... 35 °C 100 ... 250 V, 50/60 Hz 33516.18 EU Search Please contact us
4694581 37-64 Bellingham + Stanley Ltd. ±0.003 °A (546/589 nm)
±0.005 °A (405/436 nm)
-355 ... 355 °A 1 0.0001 °A ADP640 405/436/546/589 15 ... 35 °C 100 ... 250 V, 50/60 Hz 34532.35 EU Search Please contact us
4694582 37-65 Bellingham + Stanley Ltd. ±0.003 °A (546/589 nm)
±0.005 °A (365/405/436 nm)
-355 ... 355 °A 1 0.0001 °A ADP650 365/405/436/546/589 15 ... 35 °C 100 ... 250 V, 50/60 Hz 35548.53 EU Search Please contact us
4694583 37-66 Bellingham + Stanley Ltd. ±0.003 °A (546/589 nm)
±0.005 °A (325/365/405/436 nm)
-355 ... 355 °A 1 0.0001 °A ADP660 325/365/405/436/546/589 15 ... 35 °C 100 ... 250 V, 50/60 Hz 36561.76 EU Search Please contact us
4694584 37-67 Bellingham + Stanley Ltd. ±0.003 °A (546/589/633 nm)
±0.005 °A (325/365/405/436 nm)
-355 ... 355 °A 1 0.0001 °A ADP670 325/365/405/436/546/589/633 15 ... 35 °C 100 ... 250 V, 50/60 Hz 37577.94 EU Search Please contact us
Search Polarimeter AP-300 ATAGO CO.,LTD (6289)

ATAGO CO.,LTD (6289)

Polarimeter AP-300
Model AP-300 is generally used in pharmaceutical, perfume, cosmetic, industrial, chemical, and food factories and is the optimal unit for measuring angle of rotation. In addition, the built-in International Sugar Scale is widely used in sugar refineries.
The AP-300 ...
Polarimeter AP-300
Model AP-300 is generally used in pharmaceutical, perfume, cosmetic, industrial, chemical, and food factories and is the optimal unit for measuring angle of rotation. In addition, the built-in International Sugar Scale is widely used in sugar refineries.
The AP-300 has a manual calibration facility which allows the user to compensate for any differences to standard liquids and measurement values by other standard instruments.
Specifications:
Measurement range
Angle of Rotation:
International sugar scale:
-89.99 to 89.99°
-130.00 to +130.00°Z
Minimum Indication
Angle of Rotation:
International sugar scale:
0.1°
0.01°Z
Measurement accuracy
Angle of Rotation:
International sugar scale:
±0.01°
±0.03°Z
Observation tubes: 1 x 200mm and 1x 100mm
Dimensions:
Weight: 48.5 x 28.5 x 17.5cm
11.5kg
PN Manuf. PN Supplier PK Type General Price Quantity Status Add
6227906 5291 ATAGO CO.,LTD 1 AP-300 18740.79 EU Search Please contact us
Search Polarimeter P1000-LED A. Krüss Optronic GmbH (10274)

A. Krüss Optronic GmbH (10274)

Polarimeter P1000-LED
For basic lab applications and training, for example the experiment on saccharose inversion.
-Measurement of optical rotation according to the half-shade principle
-Manual adjustment on the scale
-Measurement results are read through an eyepiece and two non...
Polarimeter P1000-LED
For basic lab applications and training, for example the experiment on saccharose inversion.
-Measurement of optical rotation according to the half-shade principle
-Manual adjustment on the scale
-Measurement results are read through an eyepiece and two noniuses
-High-performance LED with a service life of 100,000 h
-Tube chamber for tubes with a length of up to 220 mm
-Includes two measurement tubes with a debubbler
-Low-maintenance, cost-effective solution
Specifications
Scale: Optical rotation (°)
Measuring range: 2 graduated circels (0 ... 180°)
Resolution: 1°
Accuracy: 0.05° (with nonius)
Light source: 1 LED with filter
Wavelength: 589 nm
Dimensions (W x D x H): 140 x 430 x 330 mm
Weight: 4.3 kg
Power supply: 110 ... 250 V, 50/60 Hz
PN Manuf. PN Supplier PK Type General Price Quantity Status Add
6059874 P1000-LED A. Krüss Optronic GmbH 1 P1000-LED 1858.94 EU Search Please contact us
Search Polarimeter P3000 A. Krüss Optronic GmbH (9044)

A. Krüss Optronic GmbH (9044)

Polarimeter P3000
Technologically high-quality polarimeter for standard applications for which a measurement accuracy of ±0.01° is sufficient and a temperature control can be omitted. Typically, the P3000 is used in the quality control of food industry.
-Measurement of optical ...
Polarimeter P3000
Technologically high-quality polarimeter for standard applications for which a measurement accuracy of ±0.01° is sufficient and a temperature control can be omitted. Typically, the P3000 is used in the quality control of food industry.
-Measurement of optical rotation
-Very short measurement time of approx. 1 s
-Easy, menu-driven adjustment
-Display of measured values in optical rotation or international sugar scale
-Suitable tubes for any type of sample
-Measurement up to an optical density of 3.0
-Temperature measurement with calibratable temperature sensor
-Reliable temperature compensation
-Chemical-resistant measurement tubes
-Compliance with GMP/GLP, pharmacopoeias [USP, BP, JP, Ph. Eur. (with tempering)], FDA, ISO, HACCP, OIML, ASTM, ICUMSA, NIST
Specifications
Scales: Optical rotation [°],
int. sugar scale [°Z]
Measuring range: ±90°
±259 °Z
Resolution: 0.01°
0.01 °Z
Accuracy: ±0.01°
±0.01 °Z
Measuring time: approx. 1 s (±90°)
Light source: 1 LED with filter
Wavelength: 589 nm
Temperature range: 0 ... 99.9 °C
Resolution: 0.1 °C
Accuracy: ±0.2 °C
Dimensions (W x D x H): 640 x 360 x 200 mm
Weight: 28 kg
Power supply: 100 ... 250 V, 50/60 Hz
PN Manuf. PN Supplier PK Type General Price Quantity Status Add
9801190 P3000 A. Krüss Optronic GmbH 1 P3000 12342.06 EU Search Please contact us
Search Polarimeter P8000 series A. Krüss Optronic GmbH (2977)

A. Krüss Optronic GmbH (2977)

Polarimeter P8000 series
Polarimeters with patented measuring method, which reduces the measuring time to approx. 1 s regardless of the sample's angle of rotation. They are used when particularly high demands are placed on measurement accuracy and on continuous data recording and data ba...
Polarimeter P8000 series
Polarimeters with patented measuring method, which reduces the measuring time to approx. 1 s regardless of the sample's angle of rotation. They are used when particularly high demands are placed on measurement accuracy and on continuous data recording and data backup. The instruments have all the functions required in FDA-regulated areas and meet all requirements of GMP/GLP and international standards.
-Fast reliable measurement up to an optical density of 3.0 OD, measurement time of approx. 1 s
-Easy, menu-driven adjustment
-Any number of freely configurable methods
-Suitable measurement tube for any type of sample
-Temperature measurement directly inside the sample
-Reliable temperature compensation
-Complete documentation of measured values
-Compliance with global standards (GMP/GLP, 21 CFR Part 11, Pharmacopoeia (USP, BP, JP, Ph. Eur.), FDA, ISO, HACCP, OIML, ASTM, ICUMSA, NIST)
Specifications
Scale: Optical rotation [°], int. sugar scale [°Z],
concentration [g/100 ml], spec. rotation
customized
Measuring range / Resolution: ±90° / 0.001°
±259 °Z / 0,01 °Z ml
Measuring time: approx. 1 s (±90°)
Light source: 1 LED with filter
Wave length: 589 nm
Temperature range: 0 ... 99.9 °C
Resolution: 0.1 °C
Accuracy: ±0.2 °C
Dimensions (W x D x H): 640 x 360 x 200 mm
Weight: 28 kg
Power supply: 110 ... 250 V, 50/60 Hz
PN Manuf. PN Supplier Accuracy Description PK Type General Price Quantity Status Add
6236652 P8000 A. Krüss Optronic GmbH ±0.003°
±0.01 °Z
Without sample temperature control 1 P8000 18043.53 EU Search Please contact us
6237632 P8000-T A. Krüss Optronic GmbH ±0.003°
±0.01 °Z
With water temperature control 1 P8000-T 20145.59 EU Search Please contact us
6285420 P8100 A. Krüss Optronic GmbH ±0.002°
±0.01 °Z
Without sample temperature control 1 P8100 22541.18 EU Search Please contact us
6285421 P8100-T A. Krüss Optronic GmbH ±0.002°
±0.01 °Z
With water temperature control 1 P8100-T 24644.12 EU Search Please contact us
6285422 P8000-TF A. Krüss Optronic GmbH ±0.003°
±0.01 °Z
With water sample temperature control, flow function 1 P8000-TF 28689.71 EU Search Please contact us
6285423 P8100-TF A. Krüss Optronic GmbH ±0.002°
±0.01 °Z
With water sample temperature control, flow function 1 P8100-TF 34477.94 EU Search Please contact us
6285424 P8000-P A. Krüss Optronic GmbH ±0.003°
±0.01 °Z
With Peltier sample temperature control 1 P8000-P 20987.35 EU Search Please contact us
6285425 P8100-P A. Krüss Optronic GmbH ±0.002°
±0.01 °Z
With Peltier sample temperature control 1 P8100-P 25526.47 EU Search Please contact us
Search Polarimeter PL1 Exacta Labcenter S.P.A. (6563)

Exacta Labcenter S.P.A. (6563)

Polarimeter PL1
Simple and sturdy instrument to measure the rotation angle of optically active substances. The measure in 180° is directly readable on two mechanical dials.

Light source: LED lamp (589.3 nm)
Polarimetiric Tubes one 100 mm and one 200 mm
Dust cover
Optical ...
Polarimeter PL1
Simple and sturdy instrument to measure the rotation angle of optically active substances. The measure in 180° is directly readable on two mechanical dials.

Light source: LED lamp (589.3 nm)
Polarimetiric Tubes one 100 mm and one 200 mm
Dust cover
Optical Glass Windows (4 pcs)
Rubber seals
Fuses
PN Manuf. PN Supplier PK Type General Price Quantity Status Add
9801259 K 71444 Exacta Labcenter S.P.A. 1 PL1 1167.24 EU Search Please contact us
Search Polarimeter Polax-2L ATAGO CO.,LTD (6290)

ATAGO CO.,LTD (6290)

Polarimeter Polax-2L
The Polax-2L (manually-operating meter with digital indicator) is widely used in the sugar, pharmaceutical, chemical, perfume and educational industries. It can accurately measure the angle of rotation (or the value in the international standard sugar scale) with eas...
Polarimeter Polax-2L
The Polax-2L (manually-operating meter with digital indicator) is widely used in the sugar, pharmaceutical, chemical, perfume and educational industries. It can accurately measure the angle of rotation (or the value in the international standard sugar scale) with easy operation.
Specifications
Measurement range
Angle of rotation:
International standard sugar scale:
-179.95 to +180°
-130 to +130°Z
Minimum unit displayed
Angle of rotation:
International standard sugar scale:
0.05°
0.1°Z
Measurement accuracy
Angle of rotation:
±0.10°
Measurement temperature range: 5 to 40°C
Observation tubes: 1 x 200mm and 1 x 100mm
Power supply: 100-240V, 50/60Hz a.c.
Power consumption: 40 VA
Dimensions:
Weight: 43 x 22 x 30cm
11.5kg
PN Manuf. PN Supplier PK Type General Price Quantity Status Add
9801398 5223 ATAGO CO.,LTD 1 Polax-2L 8817.89 EU Search Please contact us
Search Polarimeter SAC-i 589/882 ATAGO CO.,LTD (1166)

ATAGO CO.,LTD (1166)

Polarimeter SAC-i 589/882
Measurement Scales: Angle of rotation, specific rotation, International Sugar Scale, concentration, purity.

-Wavelength measurement at 589 nm (equivalent to the sodium-D line spectrum) and 882 nm (near infra red)
-Measurement stability in 13 seconds (4...
Polarimeter SAC-i 589/882
Measurement Scales: Angle of rotation, specific rotation, International Sugar Scale, concentration, purity.

-Wavelength measurement at 589 nm (equivalent to the sodium-D line spectrum) and 882 nm (near infra red)
-Measurement stability in 13 seconds (4 seconds in the high-speed and consecutive measurement mode)
-Resolution of up to 3 decimal places
-Repeatability of ±0.003° Angle of Rotation and ±0.009°Z
-Up to 999 automatic consecutive measurements followed by average value display
-Sleep and timer feature to take measurement later at specified time
-Improved usability due to touch screen technology
-Connectivity to RX Digital Refractometers for automatic purity measurement
Specifications
Measurement range
Angle of rotation:
International standard sugar scale: -89.999 to +90.000° or -360 to +360°
-259 to +259°
Resolution
Angle of rotation:
International standard sugar scale:
0.001°
0.001°Z
Measurement accuracy
Angle of rotation 589 / 882 nm:
International standard sugar scale 589 / 882 nm:
±0.005° / ±0.010° (-45 to +45°)
±0.015°Z / ±0.0700°Z (-130 to +130°Z)
Measurement temperature range: 5 to 40°C
Observation tubes: 100mm (5ml), 200mm (10ml)
Power supply: 100-240V, 50/60Hz a.c.
Dimensions:
Weight: 600 x 365 x 210mm
20kg
PN Manuf. PN Supplier PK Type General Price Quantity Status Add
6286467 5952 ATAGO CO.,LTD 1 SAC-i 589/882 16335.00 EU Search Please contact us
Search Saccharimeter ADS435/ADS438, with glass tube Bellingham + Stanley Ltd. (779366)

Bellingham + Stanley Ltd. (779366)

Saccharimeter ADS435/ADS438, with glass tube
The Saccharimeter is a dedicated polarimeter that displays results in °Z according to the ISS scale and is suitable for sugar laboratories, factories, and raw material receiving centres. The device is designed to operate in isolation but works...
Saccharimeter ADS435/ADS438, with glass tube
The Saccharimeter is a dedicated polarimeter that displays results in °Z according to the ISS scale and is suitable for sugar laboratories, factories, and raw material receiving centres. The device is designed to operate in isolation but works best when connected to an RFM300 or RFM700 refractometer. By connecting a digital refractometer, a complete purity system can be created that enables accurate purity measurements.


-High resolution 4" full colour display with easy-to-use keypad
-Continuous measurement or single measurements
-LED light source
-RFID user identification
-Data memory for over 8000 readings
-Method system with limit values
-USB "Back-up & Clone"
-User maintenance promptss
-USB (A), USB (B), and Ethernet interface


All packages are supplied with corresponding cell, lid, integrated purity, LIMS logger PC software, RFID tags, and declaration of conformity.
PN Manuf. PN Supplier Accuracy Measuring range PK Resolution Type Wavelength~nm Temperature Power supply General Price Quantity Status Add
4694560 37-25 Bellingham + Stanley Ltd. ±0.030 °Z -225 ... 225 °Z 1 0.01/0.001 °Z ADS435 589 5 ... 40 °C 100 ... 240 V, 50/60 Hz 15354.41 EU Search Please contact us
4694586 37-85 Bellingham + Stanley Ltd. ±0.060 °Z -225 ... 225 °Z 1 0.01/0.001 °Z ADS438 850 5 ... 40 °C 100 ... 240 V, 50/60 Hz 19383.82 EU Search Please contact us
Search Saccharimeter ADS435-F/ADS438-F, with funnel flow tube Bellingham + Stanley Ltd. (779386)

Bellingham + Stanley Ltd. (779386)

Saccharimeter ADS435-F/ADS438-F, with funnel flow tube
The Saccharimeter is a dedicated polarimeter that displays results in °Z according to the ISS scale and is suitable for sugar laboratories, factories, and raw material receiving centres. The device is designed to operate in isolation...
Saccharimeter ADS435-F/ADS438-F, with funnel flow tube
The Saccharimeter is a dedicated polarimeter that displays results in °Z according to the ISS scale and is suitable for sugar laboratories, factories, and raw material receiving centres. The device is designed to operate in isolation but works best when connected to an RFM300 or RFM700 refractometer. By connecting a digital refractometer, a complete purity system can be created that enables accurate purity measurements.


-High resolution 4" full colour display with easy-to-use keypad
-Continuous measurement or single measurements
-LED light source
-RFID user identification
-Data memory for over 8000 readings
-Method system with limit values
-USB "Back-up & Clone"
-User maintenance promptss
-USB (A), USB (B), and Ethernet interface


All packages are supplied with corresponding cell, lid, integrated purity, LIMS logger PC software, RFID tags, and declaration of conformity.
-Funnel flow tubes are ideal for high sample throughput
PN Manuf. PN Supplier Accuracy Measuring range PK Resolution Type Wavelength~nm Temperature Power supply General Price Quantity Status Add
4694561 37-26 Bellingham + Stanley Ltd. ±0.030 °Z -225 ... 225 °Z 1 0.01/0.001 °Z ADS435-F100 589 5 ... 40 °C 100 ... 240 V, 50/60 Hz 17073.53 EU Search Please contact us
4694562 37-27 Bellingham + Stanley Ltd. ±0.030 °Z -225 ... 225 °Z 1 0.01/0.001 °Z ADS435-F200 589 5 ... 40 °C 100 ... 240 V, 50/60 Hz 17073.53 EU Search Please contact us
4694587 37-86 Bellingham + Stanley Ltd. ±0.060 °Z -225 ... 225 °Z 1 0.01/0.001 °Z ADS438-F100 850 5 ... 40 °C 100 ... 240 V, 50/60 Hz 20488.24 EU Search Please contact us
4694588 37-87 Bellingham + Stanley Ltd. ±0.060 °Z -225 ... 225 °Z 1 0.01/0.001 °Z ADS438-F200 850 5 ... 40 °C 100 ... 240 V, 50/60 Hz 20488.24 EU Search Please contact us
Search Saccharimeter ADS455/ADS458, with XPC temperature control and metal tube Bellingham + Stanley Ltd. (779380)

Bellingham + Stanley Ltd. (779380)

Saccharimeter ADS455/ADS458, with XPC temperature control and metal tube
The Saccharimeter is a dedicated polarimeter that displays results in °Z according to the ISS scale and is suitable for sugar laboratories, factories, and raw material receiving centres. The device is designed to op...
Saccharimeter ADS455/ADS458, with XPC temperature control and metal tube
The Saccharimeter is a dedicated polarimeter that displays results in °Z according to the ISS scale and is suitable for sugar laboratories, factories, and raw material receiving centres. The device is designed to operate in isolation but works best when connected to an RFM300 or RFM700 refractometer. By connecting a digital refractometer, a complete purity system can be created that enables accurate purity measurements.


-High resolution 4" full colour display with easy-to-use keypad
-Continuous measurement or single measurements
-LED light source
-RFID user identification
-Data memory for over 8000 readings
-Method system with limit values
-USB "Back-up & Clone"
-User maintenance promptss
-USB (A), USB (B), and Ethernet interface


All packages are supplied with corresponding cell, lid, integrated purity, LIMS logger PC software, RFID tags, and declaration of conformity.
-Patented, integrated Peltier temperature control system
PN Manuf. PN Supplier Accuracy Measuring range PK Resolution Type Wavelength~nm Temperature Power supply General Price Quantity Status Add
4694564 37-45 Bellingham + Stanley Ltd. ±0.030 °Z -225 ... 225 °Z 1 0.01/0.001 °Z ADS455 589 15 ... 35 °C 100 ... 240 V, 50/60 Hz 20885.29 EU Search Please contact us
4694589 37-95 Bellingham + Stanley Ltd. ±0.060 °Z -225 ... 225 °Z 1 0.01/0.001 °Z ADS458 850 15 ... 35 °C 100 ... 240 V, 50/60 Hz 23350.00 EU Search Please contact us
Search Saccharimeter ADS455-F/ADS458-F, with XPC temperature control and funnel flow tube Bellingham + Stanley Ltd. (779389)

Bellingham + Stanley Ltd. (779389)

Saccharimeter ADS455-F/ADS458-F, with XPC temperature control and funnel flow tube
The Saccharimeter is a dedicated polarimeter that displays results in °Z according to the ISS scale and is suitable for sugar laboratories, factories, and raw material receiving centres. The device is desi...
Saccharimeter ADS455-F/ADS458-F, with XPC temperature control and funnel flow tube
The Saccharimeter is a dedicated polarimeter that displays results in °Z according to the ISS scale and is suitable for sugar laboratories, factories, and raw material receiving centres. The device is designed to operate in isolation but works best when connected to an RFM300 or RFM700 refractometer. By connecting a digital refractometer, a complete purity system can be created that enables accurate purity measurements.


-High resolution 4" full colour display with easy-to-use keypad
-Continuous measurement or single measurements
-LED light source
-RFID user identification
-Data memory for over 8000 readings
-Method system with limit values
-USB "Back-up & Clone"
-User maintenance promptss
-USB (A), USB (B), and Ethernet interface


All packages are supplied with corresponding cell, lid, integrated purity, LIMS logger PC software, RFID tags, and declaration of conformity.
-Patented, integrated Peltier temperature control system
-Funnel flow tubes are ideal for high sample throughput
PN Manuf. PN Supplier Accuracy Measuring range PK Resolution Type Wavelength~nm Temperature Power supply General Price Quantity Status Add
4694565 37-46 Bellingham + Stanley Ltd. ±0.030 °Z -225 ... 225 °Z 1 0.01/0.001 °Z ADS455-F100 589 15 ... 35 °C 100 ... 240 V, 50/60 Hz 22577.94 EU Search Please contact us
4694567 37-47 Bellingham + Stanley Ltd. ±0.030 °Z -225 ... 225 °Z 1 0.01/0.001 °Z ADS455-F200 589 15 ... 35 °C 100 ... 240 V, 50/60 Hz 22577.94 EU Search Please contact us
4694590 37-96 Bellingham + Stanley Ltd. ±0.060 °Z -225 ... 225 °Z 1 0.01/0.001 °Z ADS458-F100 850 15 ... 35 °C 100 ... 240 V, 50/60 Hz 24450.00 EU Search Please contact us
4694591 37-97 Bellingham + Stanley Ltd. ±0.060 °Z -225 ... 225 °Z 1 0.01/0.001 °Z ADS458-F200 850 15 ... 35 °C 100 ... 240 V, 50/60 Hz 24450.00 EU Search Please contact us
Search Saccharimeter ADS620P Bellingham + Stanley Ltd. (779454)

Bellingham + Stanley Ltd. (779454)

Saccharimeter ADS620P
High-precision saccharimeter with dual wavelengths Peltier temperature control for use in the sugar industry. Rapid configuration of the device from standard saccharimeter mode to a more complex sugar purity system that calculates Brix, POL, density and purity, with...
Saccharimeter ADS620P
High-precision saccharimeter with dual wavelengths Peltier temperature control for use in the sugar industry. Rapid configuration of the device from standard saccharimeter mode to a more complex sugar purity system that calculates Brix, POL, density and purity, with Brix value entered manually via the touchscreen or directly via an Ethernet connection from a connected RFM refractometer.


-High-resolution 7.4" colour touchscreen
-Simple menu structure with a method system
-RFID user identification
-VIS/NIR lamp with narrow band filter
-Suitable for standard tubes
-Integral Sugar Purity software
-USB (A), USB (B), RS232, and Ethernet interface
PN Manuf. PN Supplier Accuracy Measuring range PK Resolution Type Wavelength~nm Temperature Power supply General Price Quantity Status Add
4694585 37-72 Bellingham + Stanley Ltd. ±0.01 °Z (589 nm) -225 ... 225 °Z 1 0.002 °Z ADS620P 589/880 15 ... 35 °C 100 ... 250 V, 50/60 Hz 34532.35 EU Search Please contact us
21 items found Page 1 of 2