Loading...
You Searched For:

Search Electrofusion and electroporation system ECM 2001+, Cell fusion system Harvard Apparatus (BTX) (621712)

Harvard Apparatus (BTX) (621712)

Electrofusion and electroporation system ECM® 2001+, Cell fusion system
Multifunctional system for fast, efficient cell fusion in hybridoma production, hybrid cell formation, and nuclear transfer, as well as square wave electroporation for transfection of genes and other molecules in...
Electrofusion and electroporation system ECM® 2001+, Cell fusion system
Multifunctional system for fast, efficient cell fusion in hybridoma production, hybrid cell formation, and nuclear transfer, as well as square wave electroporation for transfection of genes and other molecules into mammalian cell lines.


-Large, easy-to-use touchscreen interface
-Preset protocols for common hybridoma, embryo manipulation, and nuclear transfer applications
-Separate electrofusion and electroporation function menus for optimised protocol programming, data organisation, and navigation
-Quick start menus for fast access to the most frequently used electrofusion and electroporation parameters
-User-defined electrofusion protocols: combination of up to 19 AC protocol steps and 1 DC protocol step
-Storage of up to 1000 user-defined protocols
The supplied safety stand connects to the generator to safely deliver high voltage electrical pulses to cuvettes.
The flat electrode generates a divergent field for cell fusion.

Scope of supply: Generator ECM® 2001+, microslide (0.5 mm / 3.2 mm), Meander fusion chamber, flat electrode, electrode adapter, connection cable, safety stand, electroporation cuvettes 1 mm / 2 mm / 4 mm (10 each), cuvette rack
PN Manuf. PN Supplier Depth~mm Height~mm PK Type Weight~kg Width~mm Plug type Rated capacity General Price Quantity Status Add
4687936 452045 Harvard Apparatus (BTX) 330 330 1 ECM® 2001+ 10 305 51808.82 EU Search Please contact us
Search Electrofusion and electroporation system ECM 2001+, Electroporation system Harvard Apparatus (BTX) (623910)

Harvard Apparatus (BTX) (623910)

Electrofusion and electroporation system ECM® 2001+, Electroporation system
Multifunctional system for fast, efficient cell fusion in hybridoma production, hybrid cell formation, and nuclear transfer, as well as square wave electroporation for transfection of genes and other molecule...
Electrofusion and electroporation system ECM® 2001+, Electroporation system
Multifunctional system for fast, efficient cell fusion in hybridoma production, hybrid cell formation, and nuclear transfer, as well as square wave electroporation for transfection of genes and other molecules into mammalian cell lines.


-Large, easy-to-use touchscreen interface
-Preset protocols for common hybridoma, embryo manipulation, and nuclear transfer applications
-Separate electrofusion and electroporation function menus for optimised protocol programming, data organisation, and navigation
-Quick start menus for fast access to the most frequently used electrofusion and electroporation parameters
-User-defined electrofusion protocols: combination of up to 19 AC protocol steps and 1 DC protocol step
-Storage of up to 1000 user-defined protocols
The supplied safety stand connects to the generator to safely deliver high voltage electrical pulses to cuvettes.

Scope of supply: Generator ECM® 2001+, safety stand, electroporation cuvettes 1 mm / 2 mm / 4 mm (10 each), cuvette rack
PN Manuf. PN Supplier Depth~mm Height~mm PK Type Weight~kg Width~mm Plug type Rated capacity General Price Quantity Status Add
4687937 452046 Harvard Apparatus (BTX) 330 330 1 ECM® 2001+ 10 305 46985.29 EU Search Please contact us
Search Electrofusion and electroporation system ECM 2001+, Embryo manipulation system Harvard Apparatus (BTX) (625985)

Harvard Apparatus (BTX) (625985)

Electrofusion and electroporation system ECM® 2001+, Embryo manipulation system
Multifunctional system for fast, efficient cell fusion in hybridoma production, hybrid cell formation, and nuclear transfer, as well as square wave electroporation for transfection of genes and other mole...
Electrofusion and electroporation system ECM® 2001+, Embryo manipulation system
Multifunctional system for fast, efficient cell fusion in hybridoma production, hybrid cell formation, and nuclear transfer, as well as square wave electroporation for transfection of genes and other molecules into mammalian cell lines.


-Large, easy-to-use touchscreen interface
-Preset protocols for common hybridoma, embryo manipulation, and nuclear transfer applications
-Separate electrofusion and electroporation function menus for optimised protocol programming, data organisation, and navigation
-Quick start menus for fast access to the most frequently used electrofusion and electroporation parameters
-User-defined electrofusion protocols: combination of up to 19 AC protocol steps and 1 DC protocol step
-Storage of up to 1000 user-defined protocols
The 0.5 and 1.0 mm microslides produce a divergent energy field ideal for efficient embryo fusion. The 3.2 mm microslide provides a homogeneous energy field for high fusion rates of hybridoma cells.

Scope of supply: Generator ECM® 2001+, microslides with round wire electrode (0.5 mm / 1.0 mm), microslide with rectangular wire electrode (3.2 mm), micrograbber adapter cables
PN Manuf. PN Supplier Depth~mm Height~mm PK Type Weight~kg Width~mm Plug type Rated capacity General Price Quantity Status Add
4687938 452047 Harvard Apparatus (BTX) 330 330 1 ECM® 2001+ 10 305 48044.12 EU Search Please contact us
Search Electrofusion and electroporation system ECM 2001+, Generator Harvard Apparatus (BTX) (620025)

Harvard Apparatus (BTX) (620025)

Electrofusion and electroporation system ECM® 2001+, Generator
Multifunctional system for fast, efficient cell fusion in hybridoma production, hybrid cell formation, and nuclear transfer, as well as square wave electroporation for transfection of genes and other molecules into mammal...
Electrofusion and electroporation system ECM® 2001+, Generator
Multifunctional system for fast, efficient cell fusion in hybridoma production, hybrid cell formation, and nuclear transfer, as well as square wave electroporation for transfection of genes and other molecules into mammalian cell lines.


-Large, easy-to-use touchscreen interface
-Preset protocols for common hybridoma, embryo manipulation, and nuclear transfer applications
-Separate electrofusion and electroporation function menus for optimised protocol programming, data organisation, and navigation
-Quick start menus for fast access to the most frequently used electrofusion and electroporation parameters
-User-defined electrofusion protocols: combination of up to 19 AC protocol steps and 1 DC protocol step
-Storage of up to 1000 user-defined protocols
Scope of supply: Generator ECM® 2001+, high voltage output cable 1.5 m, adapter set
PN Manuf. PN Supplier Depth~mm Height~mm PK Type Weight~kg Width~mm Plug type Rated capacity General Price Quantity Status Add
4687940 452049 Harvard Apparatus (BTX) 330 330 1 ECM® 2001+ 10 305 45838.24 EU Search Please contact us
Search Electrofusion and electroporation system ECM 2001+, Hybridoma production system Harvard Apparatus (BTX) (627933)

Harvard Apparatus (BTX) (627933)

Electrofusion and electroporation system ECM® 2001+, Hybridoma production system
Multifunctional system for fast, efficient cell fusion in hybridoma production, hybrid cell formation, and nuclear transfer, as well as square wave electroporation for transfection of genes and other mol...
Electrofusion and electroporation system ECM® 2001+, Hybridoma production system
Multifunctional system for fast, efficient cell fusion in hybridoma production, hybrid cell formation, and nuclear transfer, as well as square wave electroporation for transfection of genes and other molecules into mammalian cell lines.


-Large, easy-to-use touchscreen interface
-Preset protocols for common hybridoma, embryo manipulation, and nuclear transfer applications
-Separate electrofusion and electroporation function menus for optimised protocol programming, data organisation, and navigation
-Quick start menus for fast access to the most frequently used electrofusion and electroporation parameters
-User-defined electrofusion protocols: combination of up to 19 AC protocol steps and 1 DC protocol step
-Storage of up to 1000 user-defined protocols
The coaxial chambers have identical electrical characteristics to allow direct scale-up to production once the pulse parameters have been optimised. Coaxial optimisation chamber with transparent bottom allows visualisation of the cell alignment by inverted or regular microscope.

Scope of supply: Generator ECM® 2001+, coaxial optimisation chamber (2 ml), coaxial production chamber (9 ml), adapter set, cytofusion medium C (500 ml)
PN Manuf. PN Supplier Depth~mm Height~mm PK Type Weight~kg Width~mm Plug type Rated capacity General Price Quantity Status Add
4687939 452048 Harvard Apparatus (BTX) 330 330 1 ECM® 2001+ 10 305 47382.35 EU Search Please contact us
Search Electroporation cuvettes Plus Harvard Apparatus (BTX) (1251)

Harvard Apparatus (BTX) (1251)

Electroporation cuvettes Plus
BTX Cuvettes Plus are designed for use in electroporation and electrofusion of bacteria, yeast, insect, plant and mammalian cells. Each sterilized Cuvettes Plus package includes a disposable cuvette and a transfer pipette, which is used for removal of the sa...
Electroporation cuvettes Plus
BTX Cuvettes Plus are designed for use in electroporation and electrofusion of bacteria, yeast, insect, plant and mammalian cells. Each sterilized Cuvettes Plus package includes a disposable cuvette and a transfer pipette, which is used for removal of the sample after electroporation. The cuvettes are molded with embedded polished aluminum electrodes, and gamma irradiated for guaranteed sterility.
Three electrode gap sizes are available:
-1mm for bacteria and yeast
-2mm for all cell types
-4mm for mammalian cells
BTX cuvette Plus can obtain high field strengths up to 25.0 kV/cm. Round caps are leak resistant and allow for quick and easy removal. For research use only. Can be used with electroporation systems from different manufacturers (not suitable for units from Eppendorf).
PN Manuf. PN Supplier Capacity Material PK Sterile Type Colour closure Max. capacity~µl Min. capacity~µl General Price Quantity Status Add
6282773 450124 Harvard Apparatus (BTX) 20 ... 90 µl 50 yes Grey 90 20 420.59 EU Search Please contact us
6282774 450125 Harvard Apparatus (BTX) 40 ... 400 µl 50 yes blue 400 40 420.59 EU Search Please contact us
6282775 450126 Harvard Apparatus (BTX) 80 ... 800 µl 50 yes yellow 800 80 420.59 EU Search Please contact us
6282777 450134 Harvard Apparatus (BTX) 20 ... 90 µl 10 yes Grey 90 20 124.27 EU Search Please contact us
6282778 450135 Harvard Apparatus (BTX) 40 ... 400 µl 10 yes blue 400 40 131.92 EU Search Please contact us
6282779 450136 Harvard Apparatus (BTX) 80 ... 800 µl 10 yes yellow 800 80 131.92 EU Search Please contact us
Search Electroporation System ECM 399 Harvard Apparatus (BTX) (1220)

Harvard Apparatus (BTX) (1220)

Electroporation System ECM® 399
The ECM® 399 is an electroporation system for the simple transformation of bacteria and yeast cells. It produces exponential decay waves and is designed to deliver the field strengths and pulse lengths required for transformations. The ECM® 399...
Electroporation System ECM® 399
The ECM® 399 is an electroporation system for the simple transformation of bacteria and yeast cells. It produces exponential decay waves and is designed to deliver the field strengths and pulse lengths required for transformations. The ECM® 399 is ideal for basic transformation in research and academic environments. It is easy to operate, cost effective, compact in size and portable.

Applications: Transformation of bacteria, yeast, fungus.

Scope of supply: Generator ECM® 399 , PEP cuvette holder, Cuvettes 1 mm, 2 mm, 4 mm (10 each) and Cuvette Rack
PN Manuf. PN Supplier PK Type Weight~kg Depth Height Width Plug type Rated capacity General Price Quantity Status Add
6274057 450000 Harvard Apparatus (BTX) 1 BTX ECM 399 3.2 6729.93 EU Search Please contact us
Search Electroporation system ECM 830 Harvard Apparatus (BTX) (618809)

Harvard Apparatus (BTX) (618809)

Electroporation system ECM® 830
The versatile electroporation system is suitable for bacterial and yeast cell transformations, as well as for transfections of mammalian cells and tissues. The supplied safety dome connects to the generator to safely deliver high-voltage electrical pul...
Electroporation system ECM® 830
The versatile electroporation system is suitable for bacterial and yeast cell transformations, as well as for transfections of mammalian cells and tissues. The supplied safety dome connects to the generator to safely deliver high-voltage electrical pulses to cuvettes. Up to two cuvettes can be electroporated simultaneously.


-Large, easy-to-use touchscreen interface
-Preset protocols for commonly used mammalian cell lines and tissues
-Storage of up to 1000 user-defined protocols
-Safety functions: Pre-pulse resistance check, arc protection, and over-current pulse abort
-Protocol of each delivered pulse for quality control and troubleshooting


Scope of supply: Generator ECM® 830, safety dome, electroporation cuvettes 1 mm / 2 mm / 4 mm (10 each), cuvette rack
Capacitance LV mode: 3775 µF
Capacitance HV mode: 85 µF
Voltage LV mode: 5 ... 500 V
Voltage HV mode: 505 ... 3000 V
Multiple pulse: 1 ... 99 pulses per sample
Pulse length LV mode: 10 µs ... 999 ms
Pulse length HV mode: 10 µs ... 600 µs
Pulse interval: 100 ms ... 10 s
Charging time LV mode: <7 s
Charging time HV mode: <4 s
PN Manuf. PN Supplier Depth~mm Height~mm PK Type Weight~kg Width~mm Power supply Dimensions (WxDxH) General Price Quantity Status Add
4687942 452052 Harvard Apparatus (BTX) 286 216 1 ECM® 830 7.3 324 100 ... 240 V, 50 ... 60 Hz 324 x 286 x 216 mm 16347.42 EU Search Please contact us
Search Electroporation system Gemini Twin Wave SC, Complete system Harvard Apparatus (BTX) (636339)

Harvard Apparatus (BTX) (636339)

Electroporation system Gemini Twin Wave SC, Complete system
The Gemini Twin Wave devices are flexible systems that can generate both square wave and exponential decay waves. Ideally suited for all electroporation requirements. The waveform combination allows eukaryotic and prokaryotic ce...
Electroporation system Gemini Twin Wave SC, Complete system
The Gemini Twin Wave devices are flexible systems that can generate both square wave and exponential decay waves. Ideally suited for all electroporation requirements. The waveform combination allows eukaryotic and prokaryotic cells to be electroporated easily and efficiently in cuvettes with a single device. Prokaryotic cells typically respond well to exponential decay wave pulses, while eukaryotic cells are most efficiently transfected with square wave pulses.


-Large, user-friendly touchscreen interface
-Universal electroporation for transfection of cells in vitro, in vivo, in ovo, and adherent forms
-Preset protocols include the most common eukaryotic and prokaryotic cell types
-User-defined protocols: protocols can be added and modified without limits
-Safety functions: Pre-pulse resistance check, arc protection, and over-current pulse abort
-Data protocols store parameters of all delivered pulses for quality control and troubleshooting purposes
-Storage of over 1000 protocols
The supplied safety dome connects to the generator to safely deliver high-voltage electrical pulses to cuvettes. Up to two cuvettes can be electroporated simultaneously.

Scope of supply: Generator Gemini SC, safety dome, electroporation cuvettes 1 mm / 2 mm / 4 mm (10 each), cuvette rack
PN Manuf. PN Supplier Depth~mm Height~mm PK Type Weight~kg Width~mm Plug type Rated capacity General Price Quantity Status Add
4687933 452042 Harvard Apparatus (BTX) 216 324 1 Gemini Twin Wave SC 7.3 286 16588.24 EU Search Please contact us
Search Electroporation system Gemini Twin Wave SC, Generator Harvard Apparatus (BTX) (631916)

Harvard Apparatus (BTX) (631916)

Electroporation system Gemini Twin Wave SC, Generator
The Gemini Twin Wave devices are flexible systems that can generate both square wave and exponential decay waves. Ideally suited for all electroporation requirements. The waveform combination allows eukaryotic and prokaryotic cells to...
Electroporation system Gemini Twin Wave SC, Generator
The Gemini Twin Wave devices are flexible systems that can generate both square wave and exponential decay waves. Ideally suited for all electroporation requirements. The waveform combination allows eukaryotic and prokaryotic cells to be electroporated easily and efficiently in cuvettes with a single device. Prokaryotic cells typically respond well to exponential decay wave pulses, while eukaryotic cells are most efficiently transfected with square wave pulses.


-Large, user-friendly touchscreen interface
-Universal electroporation for transfection of cells in vitro, in vivo, in ovo, and adherent forms
-Preset protocols include the most common eukaryotic and prokaryotic cell types
-User-defined protocols: protocols can be added and modified without limits
-Safety functions: Pre-pulse resistance check, arc protection, and over-current pulse abort
-Data protocols store parameters of all delivered pulses for quality control and troubleshooting purposes
-Storage of over 1000 protocols
Scope of supply: Generator Gemini SC
PN Manuf. PN Supplier Depth~mm Height~mm PK Type Weight~kg Width~mm Plug type Rated capacity General Price Quantity Status Add
4687934 452043 Harvard Apparatus (BTX) 216 324 1 Gemini Twin Wave SC 7.3 286 15485.29 EU Search Please contact us
Search Electroporation system Gemini Twin Wave X2, Complete system Harvard Apparatus (BTX) (640859)

Harvard Apparatus (BTX) (640859)

Electroporation system Gemini Twin Wave X2, Complete system
The Gemini Twin Wave devices are flexible systems that can generate both square wave and exponential decay waves. Ideally suited for all electroporation requirements. The waveform combination allows eukaryotic and prokaryotic ce...
Electroporation system Gemini Twin Wave X2, Complete system
The Gemini Twin Wave devices are flexible systems that can generate both square wave and exponential decay waves. Ideally suited for all electroporation requirements. The waveform combination allows eukaryotic and prokaryotic cells to be electroporated easily and efficiently in cuvettes or plates with a single device. Prokaryotic cells typically respond well to exponential decay wave pulses, while eukaryotic cells are most efficiently transfected with square wave pulses.


-Large, user-friendly touchscreen interface
-Universal electroporation for transfection of cells in vitro, in vivo, in ovo, and adherent forms
-Preset protocols include the most common eukaryotic and prokaryotic cell types
-User-defined protocols: protocols can be added and modified without limits
-Safety functions: Pre-pulse resistance check, arc protection, and over-current pulse abort
-Data protocols store parameters of all delivered pulses for quality control and troubleshooting purposes
-Storage of over 1000 protocols
-Pulse interval: 5 to 30 s (exponential decay pulse), 0.1 to 10 s (square wave pulse)
The supplied safety dome connects to the generator to safely deliver high-voltage electrical pulses to cuvettes. Up to two cuvettes can be electroporated simultaneously.

Scope of supply: Generator Gemini X2, safety dome, electroporation cuvettes 1 mm / 2 mm / 4 mm (10 each), cuvette rack
PN Manuf. PN Supplier Depth~mm Height~mm PK Type Weight~kg Width~mm Plug type Rated capacity General Price Quantity Status Add
4687931 452040 Harvard Apparatus (BTX) 216 324 1 Gemini Twin Wave X2 7.3 286 19391.18 EU Search Please contact us
Search Electroporation system Gemini Twin Wave X2, Generator Harvard Apparatus (BTX) (646971)

Harvard Apparatus (BTX) (646971)

Electroporation system Gemini Twin Wave X2, Generator
The Gemini Twin Wave devices are flexible systems that can generate both square wave and exponential decay waves. Ideally suited for all electroporation requirements. The waveform combination allows eukaryotic and prokaryotic cells to...
Electroporation system Gemini Twin Wave X2, Generator
The Gemini Twin Wave devices are flexible systems that can generate both square wave and exponential decay waves. Ideally suited for all electroporation requirements. The waveform combination allows eukaryotic and prokaryotic cells to be electroporated easily and efficiently in cuvettes or plates with a single device. Prokaryotic cells typically respond well to exponential decay wave pulses, while eukaryotic cells are most efficiently transfected with square wave pulses.


-Large, user-friendly touchscreen interface
-Universal electroporation for transfection of cells in vitro, in vivo, in ovo, and adherent forms
-Preset protocols include the most common eukaryotic and prokaryotic cell types
-User-defined protocols: protocols can be added and modified without limits
-Safety functions: Pre-pulse resistance check, arc protection, and over-current pulse abort
-Data protocols store parameters of all delivered pulses for quality control and troubleshooting purposes
-Storage of over 1000 protocols
-Pulse interval: 5 to 30 s (exponential decay pulse), 0.1 to 10 s (square wave pulse)
Scope of supply: Generator Gemini X2
PN Manuf. PN Supplier Depth~mm Height~mm PK Type Weight~kg Width~mm Plug type Rated capacity General Price Quantity Status Add
4687932 452041 Harvard Apparatus (BTX) 216 324 1 Gemini Twin Wave X2 7.3 286 18720.59 EU Search Please contact us
Search Electroporation system Gemini Twin Wave X2, HT system Harvard Apparatus (BTX) (652940)

Harvard Apparatus (BTX) (652940)

Electroporation system Gemini Twin Wave X2, HT system
The Gemini Twin Wave devices are flexible systems that can generate both square wave and exponential decay waves. Ideally suited for all electroporation requirements. The waveform combination allows eukaryotic and prokaryotic cells to...
Electroporation system Gemini Twin Wave X2, HT system
The Gemini Twin Wave devices are flexible systems that can generate both square wave and exponential decay waves. Ideally suited for all electroporation requirements. The waveform combination allows eukaryotic and prokaryotic cells to be electroporated easily and efficiently in cuvettes or plates with a single device. Prokaryotic cells typically respond well to exponential decay wave pulses, while eukaryotic cells are most efficiently transfected with square wave pulses.


-Large, user-friendly touchscreen interface
-Universal electroporation for transfection of cells in vitro, in vivo, in ovo, and adherent forms
-Preset protocols include the most common eukaryotic and prokaryotic cell types
-User-defined protocols: protocols can be added and modified without limits
-Safety functions: Pre-pulse resistance check, arc protection, and over-current pulse abort
-Data protocols store parameters of all delivered pulses for quality control and troubleshooting purposes
-Storage of over 1000 protocols
-Pulse interval: 5 to 30 s (exponential decay pulse), 0.1 to 10 s (square wave pulse)
With the supplied HT-200 plate handler, 96-well electroporation plates can be processed. The plate handler delivers a single pulse to the wells of the plate, using the parameters set in the generator.

Scope of supply: Generator Gemini X2, safety dome, electroporation cuvettes 1 mm / 2 mm / 4 mm (10 each), cuvette rack, HT-200 plate handler, electroporation plate 2 mm and 4 mm gap
PN Manuf. PN Supplier Depth~mm Height~mm PK Type Weight~kg Width~mm Plug type Rated capacity General Price Quantity Status Add
4687935 452044 Harvard Apparatus (BTX) 216 324 1 Gemini Twin Wave X2 7.3 286 28411.76 EU Search Please contact us
13 items found Page 1 of 1
BDL to-top