Search Motor-driven piston burette Titronic 300 Xylem Analytics Germany (SI) (1509)

Xylem Analytics Germany (SI) (1509)

Motor-driven piston burette Titronic® 300
Motor-driven piston burette with 20 or 50ml dosing unit. For manual titrations and highly precise dosing tasks. The TITRONIC® 300 can be completely controlled from a PC via the USB- or RS-232-interface. Up to 16 burettes can be connected ...
Motor-driven piston burette Titronic® 300
Motor-driven piston burette with 20 or 50ml dosing unit. For manual titrations and highly precise dosing tasks. The TITRONIC® 300 can be completely controlled from a PC via the USB- or RS-232-interface. Up to 16 burettes can be connected to one another via the RS232 interface according to the daisy chain principle.

T 300/20 M1: Basic unit without magnetic stirrer with ready to use assembled 20 ml dosing unit TZ 3130 with hoses, fittings and titration tip, controller TZ 3880, titration clamp Z 305, stand rod TZ 1748 and power supply 100-240 V
T 300/50 M1: as T 300/20 M1, only with ready to use assembled 50 ml dosing unit TZ 3160
T 300/20 M2: as T 300/20 M1, additionally with magnetic stirrer TM 50
T 300/50 M2: as T 300/20 M2, only with ready to use assembled 50 ml dosing unit TZ 3160
Specifications
Interfaces: USB A and B, 2x RS 232
Stirrer connection: TM 50 power supply directly through piston burette
Keyboard connection: The unit is operated using the keys on the device itself, the controller TZ 3880 and optional PC-keyboard (USB)
Display:
Volume indicator: graphics-capable TFT display
000.005 to 9999.999 ml
Display resolution: 0.005
Dosing speed: max. 100ml/min (with 50 ml unit)
Fill time: 30secs. to 999secs. adjustable (time depends on cylinder volume)
Dosing units: 20ml or 50ml dosing unit, interchangeable
Burette resolution: 8000
Dispensing accuracy: 0.15% system measurement deviation, 0.05% accidental measurement deviation determined in accordance with EN ISO 8665, Part 3
Supply requirements: 230V, 50/60Hz
Conformity: ISO 8665, Part 6
CE mark: EMC: 2004/108/EG; safety EG- Directive 2006/95
PN Manuf. PN Supplier Burette attachment~ml PK Type General Price Quantity Status Add
9863180 285225800 Xylem Analytics Germany (SI) 20 1 T 300/20 M1 2947.55 EU Search Please contact us
9863181 285225810 Xylem Analytics Germany (SI) 50 1 T 300/50 M1 2947.96 EU Search Please contact us
9863182 285225820 Xylem Analytics Germany (SI) 20 1 T 300/20 M2 3277.51 EU Search Please contact us
9863183 285225830 Xylem Analytics Germany (SI) 50 1 T 300/50 M2 3277.11 EU Search Please contact us
Search Motor-driven piston burette TITRONIC 500 Xylem Analytics Germany (SI) (7598)

Xylem Analytics Germany (SI) (7598)

Motor-driven piston burette TITRONIC® 500
Motor-driven piston burette with intelligent exchangeable doing units with automatic recognition of unit size and reagent data. Besides manual titration and highly precise dosing tasks the TITRONIC® 500 can also be used for the preparatio...
Motor-driven piston burette TITRONIC® 500
Motor-driven piston burette with intelligent exchangeable doing units with automatic recognition of unit size and reagent data. Besides manual titration and highly precise dosing tasks the TITRONIC® 500 can also be used for the preparation of solutions by entering the weights. The connection of an analytical balance allows the easy automatisation of the solution preparation. The TITRONIC® 500 can completely controlled from a PC via the USB- or RS-232-interface. Up to 16 burettes can be connected to one another via the RS232 interface according to the daisy chain principle.

T 500: TITRONIC® 500 basic unit without magnetic stirrer, with stand rod TZ 1510, titration clamp Z 305, controller TZ 3880, power supply 100 - 240 V

T 500-M1: TITRONIC® 500 basic unit with magnetic stirrer TM 235, with stand rod TZ 1510, titration clamp Z 305, controller TZ 3880, power supply 100 - 240 V

T 500-M2/20: TITRONIC® 500 basic unit with magnetic stirrer TM 235 and exchangeable unit WA 20, with stand rod TZ 1510, titration clamp Z 305, controller TZ 3880, power supply 100 - 240 V
Technical specification
Interfaces: 3x USB (2 x USB A and 1x USB B), 2 x RS-232-C, 1 x LAN
Stirrer connection: TM 235 or alternative paddle stirrer
Keyboard: The unit is operated using the keys on the device itself., the controller TZ 3880 and optional PC-keyboard (USB)
Display: graphics-capable 3,5" TFT display
Volume display: 00.00 to 999.9ml
Display resolution: 0.001ml (depending on exchangeable unit)
Dosing speed: max. 100ml/min (with 50ml unit)
Filling speed: min. 20 to 999 sec adjustable (time according to the cylinder volume)
Exchangeable units: 5, 10, 20ml or 50ml exchangeable units with reagent recognition
Burette resolution: 20000 steps
Dosing accuracy: systematic error 0.15%, random error 0.05% in compliance with EN ISO 8655-6
Netzanschluss: 100-240V; 50/60Hz
Conformity: ISO 8655, part 6
CE-mark: EMC: 2004/108/EG; safety EG- Directive 2006/95
PN Manuf. PN Supplier Description PK Type General Price Quantity Status Add
9863210 285220200 Xylem Analytics Germany (SI) Basic unit 1 T 500 3583.13 EU Search Please contact us
9863211 285220210 Xylem Analytics Germany (SI) With magnetic stirrer 1 T 500-M1 4147.76 EU Search Please contact us
9863212 285220220 Xylem Analytics Germany (SI) With magnetic stirrer and 20ml exchangeable unit 1 T 500-M2/20 5282.35 EU Search Please contact us