Loading...
You Searched For:

Your filters:

LLG Labware (1297)

Spectrophotometer LLG-uniSPEC 2 and 4
High-quality and cost-efficient UV/VIS spectrophotometers for pharmaceutical, biochemical and clinical lab applications.
Suitable for different measurement types such as kinetics, wavelength scans, quantitative analysis, multi-wavelength an...
Spectrophotometer LLG-uniSPEC 2 and 4
High-quality and cost-efficient UV/VIS spectrophotometers for pharmaceutical, biochemical and clinical lab applications.
Suitable for different measurement types such as kinetics, wavelength scans, quantitative analysis, multi-wavelength and DNA/Protein analysis.

Available in two versions:
LLG-uniSPEC 2 for standard routine measurements and uniSPEC 4 suitable for complex measurements e.g. required for quality controls. LLG-uniSPEC 4 features a small band width and a high wavelength accuracy. Both units can store and save 200 calibration curves. A pre-adjusted lamp design allows a fast and easy lamp replacement Both lamps can be individually turned on/off to extend the durability. Both versions can be used either as stand-alone units or can be operated via a PC by using the supplied software.
-Single beam system, grid with 1200 lines / mm
-Silicon photodiode detector
-Parallel port for printer output
-USB port
-4 position cell holder (10 mm) included
-Additional cell holders optionally available
-LCD display
-Deuterium and tungsten lamp
-Automatic wavelength adjustment

Scope of supply: LLG-uniSPEC 2 or 4 Photometer, software for connection to PC, 4 glass cells and 2 quartz cells.
Specifications LLG-uniSPEC 2 // LLG-uniSPEC 4
Optical System: Single beam, Grating 1200 lines/mm, Silicium photodiode detector
Wavelength range:
Bandwidth: 190 to 1100 nm
2 nm // 1.8 nm
Wavelength accuracy:
Wavelength repeatability:
Wavelength setting: ± 0.5 nm // ± 0.3 nm
0.3 nm // 0.2 nm
automatic
Photometric accuracy:
Photometric repeatability:
Photometric range: ± 0.5 % T // ± 0.3 % T
0.3 % T // 0.2 % T
-0.3-3 A, 0-200 % T, 0-9999 C
Stability:
Stray light: ±0.002 A/h at 500 nm
≤0.1 %T // ≤0.05 %T at 220 nm, 360 nm
Data output:
Printer port:
Display: USB port
parallel port
128 x 64 Dots LCD // 320 x 240 Dots LCD
Standard cell holder:
Lamps: 4-position 10 mm cell changer
D2 lamp and W lamp
Dimension (W x D x H):
Weight: 460 x 360 x 225 mm // 625 x 430 x 206 mm
18 kg // 28 kg
Power supply: 220 V/50 Hz or 110 V/60 Hz
Warranty: 3 years
PN Manuf. PN Supplier PK Type Plug type General Price Quantity Status Add
6263610 6263610 LLG Labware 1 LLG-uniSPEC 2 EU 6104.95 EU Search 20 Days
6263620 6263620 LLG Labware 1 LLG-uniSPEC 4 EU 8518.82 EU Search Please contact us
Search Reflectance spectrophotometer TR 500 The Tintometer Limited (11103)

The Tintometer Limited (11103)

Reflectance spectrophotometer TR 500
Ergonomic and flexible reflection spectrophotometers for measuring samples in different industries including food, medicine, coatings and plastics. The on-board camera-based locator and the black and white calibration plates ensure precise measurement...
Reflectance spectrophotometer TR 500
Ergonomic and flexible reflection spectrophotometers for measuring samples in different industries including food, medicine, coatings and plastics. The on-board camera-based locator and the black and white calibration plates ensure precise measurements and results at all times.


-CMOS sensor (256 picture elements, double array)
-Intuitive 3.5 inch TFT color LCD (capacitive), symbol-based
-Free PC-based OnShade software which allows graphs and statistical process control
-Operation languages: English, French, German, Spanish, Portuguese, Chinese
-Customer-specific apertures
-External memory with 2000 standards and 20000 samples


Scope of supply: Reflectance spectrophotometer, OnShade PC software, black and white calibration board (white tile and black interface), dust cover, USB cable, external DC power supply, USB stick with user manual in the operating languages, carrying case
Specifications
Optical geometry: di: 8°, de: 8°
Specular component: SCI, SCE
Colour space: CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter Lab
Colour difference formular: DE*ab, DE*uv, DE*94, DE*cmc (2:1), DE*cmc (1:1), DE*00v, DE (Hunter)
Other colorimetic index: WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), TI (ASTM, E313, CIE/ISO), metamerism index (MI), staining fastness, colour fastness and strength, opacity
Spectral range: 400 ... 700 nm
Spectral interval: 10 nm
Memory: 2000 standards, 20000 samples
Interface: USB, Bluetooth® 4.0
Light source: combined LED light
Illuminant: D65, A, C, D50, D55, D75, F2, F7, F11
Repeatability: MAV/SCI: DE ≤0.05
Inter instrument agreement: MAV/SCI: DE ≤0.2
Dimensions (W x D x H): 184 x 105 x 77 mm
PN Manuf. PN Supplier PK Type Aperture mm General Price Quantity Status Add
4672484 403040 The Tintometer Limited 1 TR 500 8 8406.01 EU Search Please contact us
4672485 403041 The Tintometer Limited 1 TR 500 4 8372.06 EU Search Please contact us
4672486 403042 The Tintometer Limited 1 TR 500 1 x 3 8372.06 EU Search Please contact us
Search Reflectance spectrophotometer TR 515 The Tintometer Limited (729044)

The Tintometer Limited (729044)

Reflectance spectrophotometer TR 515
Ergonomic and flexible reflection spectrophotometers for measuring samples in different industries including food, medicine, coatings and plastics. The on-board camera-based locator and the black and white calibration plates ensure precise measurement...
Reflectance spectrophotometer TR 515
Ergonomic and flexible reflection spectrophotometers for measuring samples in different industries including food, medicine, coatings and plastics. The on-board camera-based locator and the black and white calibration plates ensure precise measurements and results at all times.


-CMOS sensor (256 picture elements, double array)
-Intuitive 3.5 inch TFT color LCD (capacitive), symbol-based
-Free PC-based OnShade software which allows graphs and statistical process control
-Operation languages: English, French, German, Spanish, Portuguese, Chinese
-Switchable aperture (? 8 mm/? 4 mm) for adapting the measurement size to the surface
-With the 45°/0° geometry, the device can measure the reflectance colour spectra of samples. This enables it to determine accurate colour difference values, formulas and indices in common colour spaces
-External memory with 1000 standards and 30000 samples


Scope of supply: Reflectance spectrophotometer, OnShade PC software, black and white calibration board (white tile and black light trap), dust cover, USB cable, external DC power supply, USB stick with user manual in English and Chinese, carrying case
Specifications
Optical geometry: 45°/0°
Colour space: CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter Lab
Colour difference formular: DE*ab, DE*uv, DE*94, DE*cmc (2:1), DE*cmc (1:1), DE*00v, DE (Hunter)
Other colorimetic index: WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), metamerism index (MI), staining fastness, colour fastness and strength, opacity
Spectral range: 400 ... 700 nm
Spectral interval: 10 nm
Memory: 1000 standards, 30000 samples
Interface: USB, Bluetooth® 4.0
Light source: combined LED light, UV light
Illuminant: D65, A, C, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12
Inter instrument agreement: Within DE*ab 0.15 (Average for 12 BCRA Series II colour tiles)
Dimensions (W x D x H): 184 x 105 x 77 mm
PN Manuf. PN Supplier PK Type Aperture mm General Price Quantity Status Add
6325549 403032 The Tintometer Limited 1 TR 515 10/8 + 5/4 11468.39 EU Search Please contact us
Search Reflectance spectrophotometer TR 520 The Tintometer Limited (11127)

The Tintometer Limited (11127)

Reflectance spectrophotometer TR 520
Ergonomic and flexible reflection spectrophotometers for measuring samples in different industries including food, medicine, coatings and plastics. The on-board camera-based locator and the black and white calibration plates ensure precise measurement...
Reflectance spectrophotometer TR 520
Ergonomic and flexible reflection spectrophotometers for measuring samples in different industries including food, medicine, coatings and plastics. The on-board camera-based locator and the black and white calibration plates ensure precise measurements and results at all times.


-CMOS sensor (256 picture elements, double array)
-Intuitive 3.5 inch TFT color LCD (capacitive), symbol-based
-Free PC-based OnShade software which allows graphs and statistical process control
-Operation languages: English, French, German, Spanish, Portuguese, Chinese
-Dual apertures
-Measurement of fluorescent materials with UV on/off
-Extended range of illuminants
-External memory with 2000 standards and 20000 samples


Scope of supply: Reflectance spectrophotometer, OnShade PC software, black and white calibration board (white tile and black interface), dust cover, USB cable, external DC power supply, USB stick with user manual in the operating languages, carrying case
Specifications
Optical geometry: di: 8°, de: 8°
Specular component: SCI, SCE
Colour space: CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter Lab
Colour difference formular: DE*ab, DE*uv, DE*94, DE*cmc (2:1), DE*cmc (1:1), DE*00v, DE (Hunter)
Other colorimetic index: WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), TI (ASTM, E313, CIE/ISO), metamerism index (MI), staining fastness, colour fastness and strength, opacity
Spectral range: 400 ... 700 nm
Spectral interval: 10 nm
Memory: 2000 standards, 20000 samples
Interface: USB, Bluetooth® 4.0
Light source: combined LED light, UV light
Illuminant: D65, A, C, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12
Repeatability: MAV/SCI: DE ≤0.03
Inter instrument agreement: MAV/SCI: DE ≤0.15
Dimensions (W x D x H): 184 x 105 x 77 mm
PN Manuf. PN Supplier PK Type Aperture mm General Price Quantity Status Add
4672487 403035 The Tintometer Limited 1 TR 520 10/8 + 5/4 11510.46 EU Search Please contact us
Search Reflectance spectrophotometer TRA 500 The Tintometer Limited (11105)

The Tintometer Limited (11105)

Reflectance spectrophotometer TRA 500
Combination of spectrophotometer TR 500 and portable docking station for precise and repeatable measurements of liquids, gels and powders. The precisely fitting docking station was specially developed for the TR 500 so that ambient lighting can not e...
Reflectance spectrophotometer TRA 500
Combination of spectrophotometer TR 500 and portable docking station for precise and repeatable measurements of liquids, gels and powders. The precisely fitting docking station was specially developed for the TR 500 so that ambient lighting can not enter the sample. Different glass cells offer a wide range of applications. With their robust shape, the devices are ideal for use in every laboratory.


-CMOS sensor (256 picture elements, double array)
-Intuitive 3.5 inch TFT color LCD (capacitive), symbol-based
-External memory with 2000 standards and 20000 samples
-Free PC-based OnShade software which allows graphs and statistical process control
-Operation languages: English, French, German, Spanish, Portuguese, Chinese
-Measurements are easy-to-read through the angled viewing window
-Integrated cover prevents the effects of extraneous light


Scope of supply: Spectrophotometer TR 500, complete TR 500 accessories, sample cover, white background plate, 3 x optical glass cells (10, 20, 30 mm)
Specifications
Optical geometry: di: 8°, de: 8°
Specular component: SCI, SCE
Colour space: CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter Lab
Colour difference formular: DE*ab, DE*uv, DE*94, DE*cmc (2:1), DE*cmc (1:1), DE*00v, DE (Hunter)
Other colorimetic index: WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), TI (ASTM, E313, CIE/ISO), metamerism index (MI), staining fastness, colour fastness and strength, opacity
Spectral range: 400 ... 700 nm
Spectral interval: 10 nm
Memory: 2000 standards, 20000 samples
Interface: USB, Bluetooth® 4.0
Light source: combined LED light
Illuminant: D65, A, C, D50, D55, D75, F2, F7, F11
Repeatibility: MAV/SCI: DE ≤0.05
Inter instrument agreement: MAV/SCI: DE ≤0.2
Dimensions (W x D x H): 207 x 170 x 130 mm
PN Manuf. PN Supplier PK Type Aperture mm General Price Quantity Status Add
4672168 403220 The Tintometer Limited 1 TRA 500 8 12359.68 EU Search Please contact us
Search Reflectance spectrophotometer TRA 520 The Tintometer Limited (11126)

The Tintometer Limited (11126)

Reflectance spectrophotometer TRA 520
Combination of spectrophotometer TR 520 and portable docking station for precise and repeatable measurements of liquids, gels and powders. The precisely fitting docking station was specially developed for the TR 520 so that ambient lighting can not e...
Reflectance spectrophotometer TRA 520
Combination of spectrophotometer TR 520 and portable docking station for precise and repeatable measurements of liquids, gels and powders. The precisely fitting docking station was specially developed for the TR 520 so that ambient lighting can not enter the sample. Different glass cells offer a wide range of applications. With their robust shape, the devices are ideal for use in every laboratory.


-CMOS sensor (256 picture elements, double array)
-Intuitive 3.5 inch TFT color LCD (capacitive), symbol-based
-External memory with 2000 standards and 20000 samples
-Free PC-based OnShade software which allows graphs and statistical process control
-Operation languages: English, French, German, Spanish, Portuguese, Chinese
-Dual apertures
-Measurement of fluorescent materials with UV on/off
-Extended range of illuminants
-Measurements are easy-to-read through the angled viewing window
-Integrated cover prevents the effects of extraneous light


Scope of supply: Spectrophotometer TR 520, complete TR 520 accessories, sample cover, white background plate, 3 x optical glass cells (10, 20, 30 mm)
Specifications
Optical geometry: di: 8°, de: 8°
Specular component: SCI, SCE
Colour space: CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter Lab
Colour difference formular: DE*ab, DE*uv, DE*94, DE*cmc (2:1), DE*cmc (1:1), DE*00v, DE (Hunter)
Other colorimetic index: WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), TI (ASTM, E313, CIE/ISO), metamerism index (MI), staining fastness, colour fastness and strength, opacity
Spectral range: 400 ... 700 nm
Spectral interval: 10 nm
Memory: 2000 standards, 20000 samples
Interface: USB, Bluetooth® 4.0
Light source: combined LED light, UV light
Illuminant: D65, A, C, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12
Repeatability: MAV/SCI: DE ≤0.03
Inter instrument agreement: MAV/SCI: DE ≤0.15
Dimensions (W x D x H): 207 x 170 x 130 mm
PN Manuf. PN Supplier PK Type Aperture mm General Price Quantity Status Add
4672167 403225 The Tintometer Limited 1 TRA 520 10/8 + 5/4 15588.36 EU Search Please contact us
Search Scanning Spectrophotometers Series 72, VIS and UV-Vis Cole-Parmer Ltd. (Jenway) (2243)

Cole-Parmer Ltd. (Jenway) (2243)

Scanning Spectrophotometers Series 72, VIS and UV-Vis
Scanning spectrophotometers from Jenway for measurements in the visible and UV range.
Model 7200 (VIS): wavelength range of 335 to 800 nm with a spectral bandwidth of 7 nm.
Model 7205 (UV-VIS): wavelength range of 198 to 800 nm ...
Scanning Spectrophotometers Series 72, VIS and UV-Vis
Scanning spectrophotometers from Jenway for measurements in the visible and UV range.
Model 7200 (VIS): wavelength range of 335 to 800 nm with a spectral bandwidth of 7 nm.
Model 7205 (UV-VIS): wavelength range of 198 to 800 nm with a spectral bandwidth of 5 nm.

Both spectrophotometers are ideal for a variety of applications in education and routine testing in clinical, veterinary, pharmaceutical and QC laboratories.

The 72 series spectrophotometers offer measurement modes for single wavelength with basic absorbance and % transmittance; concentration determination (via reference standards or calibration curves with up to 6 standards), full spectrum scanning and kinetics for up to 3 simultaneous wavelength measurements.

The colour touchscreen user interface provides fast and easy set up and navigation of the instrument. The 4" display allows full spectrum scans, quantitation curves and kinetics runs to be viewed easily. The sample chamber lid can also be left open during measurements which is ideal for samples in tall test tubes.

Including two USB ports for data storage and printer connectivity.

Optional heated 10x10 mm cuvette holder for thermostated measurements at 37 °C. More accessories available on request.
-Scanning diode array detector (DAD)
-Colour Touchscreen navigation
-Small footprint and lightweight
-Fast scan speed
-Multiple USB ports for data storage and printer connectivity
-2 years warranty on the instrument
Specifications
Optical system:
Single beam
Wavelength Range:
7200 (VIS):
7205 (UV-VIS):

Resolution
Repeatability
335 to 800 nm
198 to 800 nm
± 2 nm
± 2 nm
Spectral bandwidth:
7200 (VIS):
7205 (UV-VIS):
7 nm
5 nm
Photometric range:
Accuracy:
Stability: -0.300 to 2500 A
± 0.01 A at 1,0 A and 546 nm
± 0,005 A/h bei 0,04 A und 546 nm
Stray Light at 340 nm, %T: Concentration range:
Quantitation: ± 2500
± 2500
Kinetics: 15 bis 99999 s
Light source:
7200 (VIS):
7205 (UV-VIS):
Tungsten halogen lamp
Xenon lamp
Outputs: 2 x USB
Dimension (W x D x H):
Weight:
Power supply:
Warranty: 212 x 422 x 120 mm
2,8 kg
100-240 V, 50 / 60 Hz
2 Years
PN Manuf. PN Supplier Description PK General Price Quantity Status Add
6283459 720 001 Cole-Parmer Ltd. (Jenway) Spectrophotometer 7200 (VIS) 1 4196.11 EU Search Please contact us
6286777 720 501 Cole-Parmer Ltd. (Jenway) Spectrophotometer 7205 (UV-VIS) 1 5164.68 EU Search Please contact us
Search Spectrophotometer 7415 nano Cole-Parmer Ltd. (Jenway) (7903)

Cole-Parmer Ltd. (Jenway) (7903)

Spectrophotometer 7415 nano
For accurate, fast and reproducible measurement of sample volumes from 0.5 µl to 5 µl. Programmed for the measurement of nucleic acid concentration and purity as well as protein assays. The direct application of the sample on the measuring head eliminates the ...
Spectrophotometer 7415 nano
For accurate, fast and reproducible measurement of sample volumes from 0.5 µl to 5 µl. Programmed for the measurement of nucleic acid concentration and purity as well as protein assays. The direct application of the sample on the measuring head eliminates the need for cuvettes or sample dilution. Single measurements are performed in less than 6.5 seconds. Fast cleaning of the measuring optics simply by wiping off. Customized Android-based user interface to control the instrument, set measurement modes and retrieve results. Ethernet and USB interfaces for transfer of results, updates and printer connection as well as networking with cloud services.

-Ideal for DNA, RNA and protein determination
-Only 0.5 µl sample volume required
-For DNA concentrations up to 2 ng/µl
-7" color touch screen
-Multilingual user interface
-10 GB internal memory for methods and results
-3 years warranty, also on the xenon lamp
-Stainless steel measuring head with quartz lens
Specifications
Wavelength range: 198 ... 1000 nm
Wavelength accuracy:
Spectral bandwidth: ±2 nm
5 nm
Absorbance accuracy:
Transmittance range: ±0.01 at 1.0 A
0 ... 199.9 %
Concentration range: 2 ... 6000 ng/µl dsDNA
DNA measurement modes: dsDNA, ssDNA, RNA, Oligonucleotides, 260/280, 260/230, variable ratio
Protein measurement modes: BCA, Bradford, Lowry, Biuret, direct UV
Light source: Xenon lamp
Dimensions (W x D x H):
Weight: 275 x 400 x 220 mm
7.7 kg
Power supply: 100 ... 240 V, 50 ... 60 Hz
PN Manuf. PN Supplier PK Type General Price Quantity Status Add
4664027 747 501 Cole-Parmer Ltd. (Jenway) 1 7415 Nano 12101.76 EU Search Please contact us
Search Spectrophotometer BioDrop DUO Biochrom Ltd. (9083)

Biochrom Ltd. (9083)

Spectrophotometer BioDrop DUO
Biodrop Duo is a service-free bench-top instrument with a cuvette holder and a micro-volume sample port. The port enables absorption measurements in just 0.5 µl sample volume without cuvettes. Ideal for rapid serial measurements of DNA, RNA or proteins. The ...
Spectrophotometer BioDrop DUO
Biodrop Duo is a service-free bench-top instrument with a cuvette holder and a micro-volume sample port. The port enables absorption measurements in just 0.5 µl sample volume without cuvettes. Ideal for rapid serial measurements of DNA, RNA or proteins. The cuvette holder offers the possibility for measurements with larger volumes with conventional 10 mm cuvettes. The instrument has a large colour touchscreen and preprogrammed applications for the measurement of DNA, RNA, oligos and proteins.
Generated data can be stored internally or transferred from the instrument using a USB flashdrive. The photometer can be operated with a PC and the supplied BioDrop Resolution Software via a USB connection. A built-in printer can also be selected for a complete stand-alone solution.
-Micro-volume sample port for minimum sample volume
-High-resolution, colour touchscreen
-Software package with preprogrammed methods for sample analysis
-USB connection for PC control and data export
-No calibration needed
-Easy cleaning of the sample port with a lint-free tissue
Specifications
Maximum concentration dsDNA: 2500 ng/µl
Detection limit: 1 ng/µl
Absorbance range: 0.3 to 2.5 A (0.3 A to 50 A, 10 mm equivalent)
Absorbance accuracy: ±0.005 A or 1 % of the reading, whichever is the greater at 546 nm
Spectral bandwidth: 5 nm
Stray light: <0.5 %T at 220 nm and 340 nm using NaNO2
Wavelength range: 190 bis 1100 nm
Wavelength accuracy: ±2 nm
Light source: Pulsed Xenon lamp
Dimensions (W x D x H): 260 x 420 x 185 mm
Weight: 3 kg
Power supply: 90-250 V, 50/60 Hz, max 50 VA
PN Manuf. PN Supplier Description PK General Price Quantity Status Add
6313967 80-3006-68 Biochrom Ltd. BioDrop DUO 1 17544.00 EU Search Please contact us
6313968 80-3006-69 Biochrom Ltd. BioDrop DUO with printer 1 18443.81 EU Search Please contact us
Search Spectrophotometer Models 6300 VIS / 6305 UV-VIS Cole-Parmer Ltd. (Jenway) (6449)

Cole-Parmer Ltd. (Jenway) (6449)

Spectrophotometer Models 6300 VIS / 6305 UV-VIS
Models 6300 and 6305 are general purpose visible and UV/Visible range spectrophotometers which are suited to a wide range of applications in education and quality control.
-Simple operation
-Versatile sampling system
-G.L.P. compli...
Spectrophotometer Models 6300 VIS / 6305 UV-VIS
Models 6300 and 6305 are general purpose visible and UV/Visible range spectrophotometers which are suited to a wide range of applications in education and quality control.
-Simple operation
-Versatile sampling system
-G.L.P. compliant
-Full interfacing capability
-Simple keypad and operating protocols designed to enable reliable operation by unskilled operators
-LCD gives simultaneous readout of wavelength and photometric result
-Error messages, prompts, mode indication and a choice of concentration units are presented in an easily understood format
-Cuvette holder allows 10mm to 100mm cells
-3 year warranty

Supplied with: Mains lead, pack 100 disposable cuvettes, 10 x 10mm cell holder, PC Application Software on CD-ROM and operating instructions.

Various accessories e.g. sipper pump, cells, cell holders, cuvettes and lamps available on request.
Specifications
Optical system:
Single beam
Wavelength
Range:

Resolution:
Accuracy:
Bandwidth:
198 to 1000nm (6305)
320 to 1000nm (6300)
1nm
±2nm
8nm, 6nm over UV range
Transmittance
Range:
Resolution:
Stray light:
Accuracy:
0 to 199.9%
0.1%
Absorbance
Range:
Resolution:
-0.300 to 1.999A
0.001A
Concentration
Range:
Resolution:
Units:
-300 to 1999
0.1/1
ppm, mg/l, g/l, M, blank %
Outputs: analogue (0 to 1999mV d.c.)
RS232 serial port
Light Source: Xenon flash lamp module (6305)
Tungsten halogen (6300)
Dimensions (W x D x H):
Weight: 365 x 272 x 160mm
6kg
Supply requirements: 230V/50Hz
PN Manuf. PN Supplier PK Type General Price Quantity Status Add
9775411 635 001 Cole-Parmer Ltd. (Jenway) 1 6305 UV-VIS 6869.84 EU Search Please contact us
9775412 630 501 Cole-Parmer Ltd. (Jenway) 1 6300 VIS 5413.81 EU Search Please contact us
10 items found Page 1 of 1
BDL to-top