Search Benchtop-Autoclaves HMT FA/-MA and -MB series HMC-EUROPE GmbH (2022)

HMC-EUROPE GmbH (2022)

Benchtop-Autoclaves HMT FA/-MA and -MB series
HMT 230/260 FA - for standard tasks:
-Certified according to regulation 93/42/EEC
-Available in 2 sizes with a volume of 16 or 24 liters
-9 sterilization programs, fully automatic: 121 °C wrapped / unwrapped solid items; with ...
Benchtop-Autoclaves HMT FA/-MA and -MB series
HMT 230/260 FA - for standard tasks:
-Certified according to regulation 93/42/EEC
-Available in 2 sizes with a volume of 16 or 24 liters
-9 sterilization programs, fully automatic: 121 °C wrapped / unwrapped solid items; with or without drying, 135 °C wrapped / unwrapped solid items; with or without drying, Liquid program: 121 °C, 40 min.
-Controlled by a microprocessor
-Simple digital display
-Water tank
-Electromechanical overheating protection
-Safety valve
-Mechanical pressure-dependent door lock
-Reset/emergency button
-Easy maintenance

HMT 230/260/300 MA - versatile table-top autoclave:
-Certified according to regulation 93/42/EEC
-Available in 3 sizes with a volume of 16, 24 or 40 liters
-Powerful integrated vacuum pump, an essential feature for sterilizing tubes and hollow components
-7 sterilization programs, fully automatic: 121 °C wrapped / unwrapped (vacuum), 134 °C wrapped / unwrapped (vacuum), Liquid and prion programs, Bowie-Dick test
-Controlled by a microprocessor
-Progress indicator
-Internal water tank
-Electromechanical overheating protection
-Electronic overpressure protection
-Pressure safety valve
-Mechanical pressure-dependent door lock
-Reset/emergency button
-Easy maintenance

HMT 260/300 MB - premium table-top autoclave:
-Certified according to regulation 93/42/EEC
-Available in 2 sizes with a volume of 24 or 40 liters
-Powerful integrated vacuum pump, an essential feature for sterilizing tubes and hollow components
-5 sterilization programs, fully automatic: Sterilization of wrapped items: 121 °C - 30 min.; 134 °C - 15 min., Sterilization of unwrapped items: 121 °C - 15 min.; 134 °C - 4 min., Individual temperature selection from 105° to 135 °C, Preset prion program
-3 test programs: leakage test, helix test, Bowie-Dick test
-Controlled by a microprocessor
-Easy operation with a LCD display
-Documentation / data storage via SD card and printer
-Drying program, 1- 60 minutes
-4 literwater tank, to be filled manually or automatically (purified water)
-Various safety features, e.g. safety valve or pressure-dependent door lock
-With modern design, easy maintenance
PN Manuf. PN Supplier Capacity~L Chamber diam. x depth~mm Height~mm Length~mm PK Rating~kW Type Width~mm General Price Quantity Status Add
4655160 22002 HMC-EUROPE GmbH 16 230 x 410 410 594 1 1.9 HMT 230 MA 522 8375.00 EU Search Please contact us
4655162 22003 HMC-EUROPE GmbH 24 260 x 450 442 655 1 2.4 HMT 260 MA 533 10899.12 EU Search Please contact us
4655164 22012 HMC-EUROPE GmbH 40 300 x 570 489 900 1 3.2 HMT 300 MA 620 15005.00 EU Search Please contact us
4655166 22014 HMC-EUROPE GmbH 24 260 x 450 440 665 1 2.7 HMT 260MB 553 13826.76 EU Search Please contact us
6237578 22004 HMC-EUROPE GmbH 16 230 x 410 410 594 1 1.9 HMT 230FA 522 7345.59 EU Search Please contact us
6287544 22021 HMC-EUROPE GmbH 40 300 x 570 489 766 1 2.3 HMT 300MB 620 17345.59 EU Search Please contact us
7980101 22005 HMC-EUROPE GmbH 24 260 x 450 442 655 1 2.4 HMT 260FA 533 9922.06 EU Search Please contact us
Search Digital horizontal autoclave Type AH R. ESPINAR S.L. (Raypa) (10009)

R. ESPINAR S.L. (Raypa) (10009)

Digital horizontal autoclave Type AH
This autoclave is microprocessor controlled and monitored with 10 sterilisation programmes of which 4 are fixed and 6 are freely selectable and has bacteriological filters included by default.
-Operating temperature range 100 °C to 134 °C
-On re...
Digital horizontal autoclave Type AH
This autoclave is microprocessor controlled and monitored with 10 sterilisation programmes of which 4 are fixed and 6 are freely selectable and has bacteriological filters included by default.
-Operating temperature range 100 °C to 134 °C
-On request, also available with B Class
-RS 232 interface
-Fully automatic functions
-With water reservoir, pre-vacuum and drying
-Case and lid shrouding are AISI 304 stainless steel
-Sterilisation chamber, lid and sealing system are AISI 316 stainless steel
-Electrical heating with protected heating elements
-Safety pressure valve
-Safety thermostat
-Automatic steam controlled by Touch Screen microprocessor
-Manual valves for emptying the sterilisation chamber and for draining steam
-Equipped with mesh stand on the chamber base and trays
-Supply requirements: 230 V 16 A single phase
PN Manuf. PN Supplier Capacity~L Chamber diam. x depth~mm Height~mm Length~mm PK Power~W Type Width~mm General Price Quantity Status Add
6267579 AHS-50-DRY R. ESPINAR S.L. (Raypa) 50 400 x 400 630 780 1 2000 AHS-50 DRY 760 15268.88 EU Search Please contact us
9851888 AHS-75-DRY R. ESPINAR S.L. (Raypa) 75 400 x 600 630 980 1 3200 AHS-75 DRY 760 17113.53 EU Search Please contact us
9851898 AH-21-L R. ESPINAR S.L. (Raypa) 21 250 x 430 425 590 1 2000 AH-21 L 680 9068.53 EU Search Please contact us
2 items found Page 1 of 1